v600-d2kr16 Omron Corporation, v600-d2kr16 Datasheet - Page 7

no-image

v600-d2kr16

Manufacturer Part Number
v600-d2kr16
Description
Electromagnetic Coupling Rfid System
Manufacturer
Omron Corporation
Datasheet
■ Read/Write (R/W) Heads with Separate Amplifier
Note: 1. Extension cables are also available. The maximum cable length is 50 m for the V600-HA51. Extension cables are not available for the
Item
Oscillation frequency
Ambient temperature
Storage temperature
Ambient humidity
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
(destruction)
Shock resistance
(destruction)
Cable length Sensor to
Wireless transmission
error detection
Indicators
Weight
2. The connectors are not water-resistant.
V600-HS51/HS61.
amplifier
Amplifier to
controller
Model
530 kHz
− 10 to 60 ° C
− 25 to 75 ° C
35% to 95%
50 M Ω min. (at 500 VDC) between cable terminals and case
1,000 VAC 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
IEC 60529: IP67
10 to 2,000 Hz, 1.5-mm single amplitude, 300 m/s
eration with 2 sweeps of 15 min each in 3 directions
1,000 m/s
2 m (fixed)
---
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
---
Approx. 70 g (with 2-m cable)
V600-HS51
2
3 times each in 3 directions (18 times total)
Sensor section
V600-HS61
Electromagnetic Coupling RFID System
2
accel-
---
IEC 60529: IP66
Installed in panel
DIN Track installa-
tion
500 m/s
---
Standard lengths of 2 m, 5 m, and 10 m (See note 1.)
Power: green; transmission: orange
Approx. 650 g (with 10-m cable)
2
3 times each in 3 directions (18 times total)
Amplifier section
10 to 2,000 Hz, 1.5-mm single am-
plitude, 300-m/s
sweeps of 11 min each in 3 direc-
tions
10 to 500 Hz, 1.0-mm single ampli-
tude, 150-m/s
sweeps of 11 min each in 3 direc-
tions
V600-HA51
V600
2
acceleration with 3
2
acceleration with 2
7

Related parts for v600-d2kr16