Si3482
4.4. System Control
The System Control routines allow a User Interface component to
4.4.1. ResetSystem
Reset the system.
Prototype:
Parameters:
Return Value:
4.4.2. RestoreFactoryDefaults
Restore the configuration to factory default values.
Prototype:
Parameters:
Return Value:
The Power Manager also resets the system after setting the configuration to default values.
4.5. Port Control
The Port Control routines allow a User Interface component to
4.5.1. SetPortControl
Set how the port is turned on and off.
Prototype:
Parameters:
Return Value:
Table 14 lists Port Control values.
If the port control is automatic, the Power Manager automatically turns the port on and off when a PD is connected
and disconnected from the port.
If the port control is forced on, the port's priority is boosted to the forced priority level. This usually results in the port
turning on. However, a forced port cannot cause a critical priority port to turn off in order to turn on the forced port.
If a forced port is granted power, the Power Manager turns on a forced port even if no PD is detected.
If the port control is forced off, the port is unconditionally turned off and held off. A forced-off port is considered to
be temporarily off, while a disabled port is considered to be permanently off.
22
Reset the System
Restore Factory Defaults
Set Port Control
Adjust Port Power
INT8 ResetSystem ( void )
None
Zero (for success) or an error code.
void RestoreFactoryDefaults ( void )
None
None
INT8 SetPortControl ( UINT8 Port, UINT8 Control )
Port
Control
Zero (for success) or an error code.
Automatic
Force On
Force Off
Control
The port number (1–48)
How the port is turned on and off.
Table 14. Port Control Values
Rev. 0.1
Value
0
1
2
PORT_CTRL_AUTOMATIC
PORT_CTRL_FORCE_OFF
PORT_CTRL_FORCE_ON
Symbol