smfl283r3s Interpoint Corp., smfl283r3s Datasheet - Page 12

no-image

smfl283r3s

Manufacturer Part Number
smfl283r3s
Description
Smfl Single And Dual Dc/dc Converters
Manufacturer
Interpoint Corp.
Datasheet
www.craneae.com
end item-level test
perfOrmed
Non-destruct bond pull
Pre-cap Inspection
Temperature Cycle (10 times)
Constant Acceleration
PIND Test
Pre burn-in test
Burn-in
Final Electrical Test MIL-PRF-38534
Radiography
Post Radiography Electrical Test
Hermeticity Test
Final visual inspection
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. Space Prototype (O), non-QML products, do not meet all of the requirements of MIL-PRF-38534.
2. Not applicable to EMI filters that have no wirebonds.
3. Not required by DSCC but performed to assure product quality.
Method 2023
Method 2017, 2032
Method 1010, Cond. C, -65°C to 150°C, ambient
Method 2001, 3000 g
Method 2020, Cond. A
Method 1015, 125°C case, typical
Group A, Subgroups 1 through 6
Method 2012
Room temperature
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Method 2009
96 hours
160 hours
2 x 160 hours (includes mid-BI test)
-55°C, +25°C, +125°C case
C
lass
H
sMFL single and dual dc/dc converters
2
and
K, MIl-PRF-38534 E
28 VoLt input – 65 Watt
Rev H - 20071102
spaCe prOtOtype (O)
Page 12 of 13
nOn-Qml
N/A
N/A
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
nvIRonMEntal
1
Crane Aerospace & Electronics Power Solutions
Class h
Qml
yes
yes
N/A
N/A
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
3
3
s
CREEnIng
Class k
Qml
yes
N/A
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
3

Related parts for smfl283r3s