ds1876 Maxim Integrated Products, Inc., ds1876 Datasheet - Page 38

no-image

ds1876

Manufacturer Part Number
ds1876
Description
Sfp Controller With Dual Ldd Interface
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ds1876T+
Manufacturer:
Maxim
Quantity:
150
SFP Controller with Dual LDD Interface
Lower Memory, Register 73h: RESERVED
Lower Memory, Register 74h: WARN
38
_____________________________________________________________________________________
74h
POWER-ON VALUE
READ ACCESS
WRITE ACCESS
A2h AND B2h MEMORY
MEMORY TYPE
This register is reserved.
POWER-ON VALUE
READ ACCESS
WRITE ACCESS
A2h AND B2h MEMORY
MEMORY TYPE
TEMP HI
BIT 7
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TEMP HI: High warning status for temperature measurement.
0 = (default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
TEMP LO: Low warning status for temperature measurement.
0 = (default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
VCC HI: High warning status for V
0 = (default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
VCC LO: Low warning status for V
the POA trip-point value. It clears itself when a V
above the low threshold.
0 = Last measurement was equal to or above threshold setting.
1 = (default) Last measurement was below threshold setting.
BMON HI: High warning status for BMON measurement.
0 = (default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
BMON LO: Low warning status for BMON measurement.
0 = (default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
PMON HI: High warning status for PMON measurement.
0 = (default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
PMON LO: Low warning status for PMON measurement.
0 = (default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
TEMP LO
N/A
N/A
N/A
N/A
3
10h
All
N/A
Different A2h and B2h memory locations
Volatile
VCC HI
VCC LO
CC
CC
measurement.
measurement. This bit is set when the V
BMON HI
CC
measurement is completed and the value is
BMON LO
PMON HI
CC
supply is below
PMON LO
BIT 0

Related parts for ds1876