2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
REFERENCE DATA
1. Maximum switching capacity
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
1,000V
10mV
100V
10V
*2 Half-wave pulse of sine wave: 11ms; detection time: 10 s
*3 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
10 A
actual load.
(SX relays are available for low level load switching [10V DC, 10mA max. level])
100mA
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. carrying current
Min. switching capacity (Reference value)*
Nominal operating power
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Temperature rise
Operate time [Set time] (at 20 C
Release time [Reset time] (at 20 C
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Switching current
1A
Between open contacts
Between contact and coil
Functional*
Destructive
Functional
Destructive
Item
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
68
2
68
2. Life curve (Resistive load)
F)
F)
1,000
1
100
10
0
3
Max. 10 ms [10 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 5 ms [10 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
(By resistive method, nominal voltage applied to the coil, contact carrying current: 2A.)
125 V DC
Approx. 3 g
Switching current, A
(1,000 Vrms for 1min: 1 Form C high sensitivity type) (Detection current: 10mA.)
1
(500 Vrms for 1min: 1 Form C high sensitivity type) (Detection current: 10mA.)
Min. 490 m/s
30 V DC
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
1 Form C
Measurement at same location as “Initial breakdown voltage” section.
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10 s.)
.11 oz
Ambient temperature: –40 C to +70 C
Single side stable (M type: 400 mW, S type: 200 mW);
Min. 980 m/s
Min. 10
2
2
latching (M type: 360 mW, S type: 180 mW)
Max. 50 m (By voltage drop 6 V DC 1A)
10 to 55 Hz at double amplitude of 5 mm
8
(10
Min. 5 10
7
Min. 100M
2
: 1 Form C latching type) (at 600 cpm)
(Half-wave pulse of sine wave: 6 ms.)
1,000 Vrms for 1min.
1,500 Vrms for 1min.
220 V DC, 250 V AC
Approx. 4g
10 A 10m V DC
(without diode)
Specifications
Min. 490 m/s
5
60 W, 125 VA
3. Contact reliability for AC loads
Tested sample: DS2E-M-DC24V 10 pcs.
Operating speed: 20 cpm.
Detection level: 200 m
2 A 30 V DC
Ag+Au clad
rated load (at 60 cpm)
Max. 65 C
2 Form C
60 cpm
3 A
(at 500V DC)
99.9
99.0
95.0
70.0
50.0
30.0
10.0
5.0
2.0
1.0
0.5
0.2
0.1
.14oz
0
2
–40 F to +158 F
10
No. of operations, 10
Approx. 7g
Min. 294 m/s
4 Form C
Weibull
probability data
100
.25oz
4
2
1,000