MBM29DL324TD Fujitsu Media Devices, MBM29DL324TD Datasheet - Page 61

no-image

MBM29DL324TD

Manufacturer Part Number
MBM29DL324TD
Description
(MBM29DL32xBD) 32M (4M X 8/2M X 16) BIT Dual Operation
Manufacturer
Fujitsu Media Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MBM29DL324TD-90PFTN
Manufacturer:
FUJI
Quantity:
270
Part Number:
MBM29DL324TD-90PFTN
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
MBM29DL32XTD/BD
-80/90/12
The manufacture and device codes can be allowed reading from selected bank. To read the manufacture and
device codes and sector protection status from non-selected bank, it is necessary to write Read/Reset command
sequence into the register and then Autoselect command should be written into the bank to be read.
If the software (program code) for Autoselect command is stored into the Flash memory, the device and
manufacture codes should be read from the other bank where is not contain the software.
To terminate the operation, it is necessary to write the Read/Reset command sequence into the register, and
also to write the Autoselect command during the operation, execute it after writing Read/Reset command
sequence.
• Byte/Word Programming
The devices are programmed on a byte-by-byte (or word-by-word) basis. Programming is a four bus cycle
operation. There are two “unlock” write cycles. These are followed by the program set-up command and data
write cycles. Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is
latched on the rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever
happens first) begins programming. Upon executing the Embedded Program Algorithm command sequence,
the system is not required to provide further controls or timings. The device will automatically provide adequate
internally generated program pulses and verify the programmed cell margin.
The system can determine the status of the program operation by using DQ
(Data Polling), DQ
(Toggle Bit),
7
6
or RY/BY. The Data Polling and Toggle Bit must be performed at the memory location which is being programmed.
The automatic programming operation is completed when the data on DQ
is equivalent to data written to this
7
bit at which time the devices return to the read mode and addresses are no longer latched. (See Table 13,
Hardware Sequence Flags.) Therefore, the devices require that a valid address to the devices be supplied by
the system at this particular instance of time. Hence, Data Polling must be performed at the memory location
which is being programmed.
Any commands written to the chip during this period will be ignored. If hardware reset occurs during the
programming operation, it is impossible to guarantee the data are being written.
Programming is allowed in any sequence and across sector boundaries. Beware that a data “0” cannot be
www.DataSheet4U.com
programmed back to a “1”. Attempting to do so may either hang up the device or result in an apparent success
according to the data polling algorithm but a read from Read/Reset mode will show that the data is still “0”. Only
erase operations can convert “0”s to “1”s.
TM
Figure 22 illustrates the Embedded Program
Algorithm using typical command strings and bus operations.
• Chip Erase
Chip erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the
“set-up” command. Two more “unlock” write cycles are then followed by the chip erase command.
Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded Erase
Algorithm command sequence the devices will automatically program and verify the entire memory for an all
zero data pattern prior to electrical erase (Preprogram function). The system is not required to provide any
controls or timings during these operations.
The system can determine the status of the erase operation by using DQ
(Data Polling), DQ
(Toggle Bit), or
7
6
RY/BY. The chip erase begins on the rising edge of the last CE or WE, whichever happens first in the command
sequence and terminates when the data on DQ
is “1” (See Write Operation Status section.) at which time the
7
device returns to read the mode.
Chip Erase Time; Sector Erase Time
All sectors + Chip Program Time (Preprogramming)
Figure 23 illustrates the Embedded Erase
TM
Algorithm using typical command strings and bus operations.