SY3545 SMC, SY3545 Datasheet - Page 4

no-image

SY3545

Manufacturer Part Number
SY3545
Description
Rubber Seal 5 Port Solenoid Valve
Manufacturer
SMC
Datasheet
Note 1) Available with up to 16 solenoids. When a large number of valves will be
Note 2) The value is for manifold base mounting (5 stations). 2 position type with single
Note 3) The weight W is the value for the manifold only. To obtain the weight with
Manifold Specifications
Manifold type
Valve stations
Port size
Weight W (g)
n: Stations
(D-sub connector)
P (SUP), R (EXH) system
A, B port piping
specifications
Valve effective
area mm²
(Cv factor)
operated simultaneously, use type B (supply/exhaust on both sides), applying
pressure to the P ports on both sides and releasing exhaust from the R ports on
both sides.
action.
solenoid valves, add the solenoid valve weights for the required number of
stations. Furthermore, when mounting supply/exhaust block assemblies on both
sides of type B with a 2 to 10 station manifold, calculate the weight W using the
formula for 11 to 16 stations.
Model
P/R
ports
A/B
ports
Note 2)
Note 3)
Note1)
Direction
Location
SY3000
SY5000
SY3000
SY5000
SY3000
SY5000
SY3000
SY5000
C6 (ø6 One-touch fitting)/C8 (ø8 One-touch fitting)
C6: P A/B 4.68 (0.26) A/B R 4.68 (0.26)
C4 (ø4 One-touch fitting)/C6 (ø6 One-touch fitting)
C8: P A/B 12.6 (0.7) A/B R 12.6 (0.7)
2 to 10 stations:
11 to 16 stations: W = 26n + 199
2 to 10 stations:
11 to 16 stations: W = 54n + 264
C10 (ø10 One-touch fitting)
C8 (ø8 One-touch fitting)
C4 (ø4 One-touch fitting)
Flat cable type 45G
Common SUP/EXH
2 to 16 stations
Plug-in type
Base
Side
W = 26n + 172
W = 54n + 227
5 Port Solenoid Valve
Note) Impact resistance: No malfunction when tested with a drop tester in the
Solenoid Specifications
SY3000
Weights
Solenoid Valve Specifications
Response Time
SY5000
Note) Based on JISB8375-1981 dynamic performance test (with coil temperature
of 20 C and at rated voltage).
External pilot
operating
pressure range
MPa
Ambient and fluid temperature C
Max. operating
frequency Hz
Manual override
Pilot
exhaust type
Lubrication
Mounting orientation
Impact/Vibration resistance m/s²
Enclosure
Type of actuation
Type of actuation
Internal pilot
operating
pressure range
MPa
2 position single
2 position double
3 position
Series
Fluid
2 position double
3 position
Rated coil voltage
Allowable voltage fluctuation
Power consumption
Surge voltage suppressor
Indicator light
2 position single
Valve model
SY3140
SY3 45
SY5140
SY5 45
Vibration resistance:No malfunction when tested with one sweep of 8.3 to
Pilot
pressure
range
Operating pressure range
3 position
2 position single
2 position double
3 position
2 position single, double
External pilot
Internal pilot
Series
2 position
3 position
2 position
3 position
axial direction and at a right angle to the main valve
and armature, one time each in both energized and
deenergized states. (Initial value)
2000Hz in the axial direction and at a right angle to the
main valve and armature, in both energized and
deenergized states. (Initial value)
2 position single
2 position double
3 position
With light/surge voltage suppressor
With light/surge voltage suppressor
Type of actuation
Note)
Response time ms
Response time ms
SY3000/5000
Main valve/pilot valve common exhaust type
Slotted locking type, Knob locking type
Pilot valve individual exhaust type
12 or less
10 or less
16 or less
19 or less
18 or less
32 or less
Pressure center
Pressure center
Exhaust center
Exhaust center
Closed center
Closed center
SY3000
Double
Double
10
10% of rated voltage
Single
Single
3
Non-locking push type
–100kPa to 0.7
Maximum 50
Not required
Unrestricted
0.15 to 0.7
0.25 to 0.7
Dust proof
0.1 to 0.7
0.2 to 0.7
24VDC
150/30
0.55W
Diode
LED
Air
SY5000
Weight g
5
3
112.6
102
51
77
82
59
46

Related parts for SY3545