LTC3805 Linear Technology, LTC3805 Datasheet - Page 10

no-image

LTC3805

Manufacturer Part Number
LTC3805
Description
Adjustable Frequency Current Mode Flyback DC/DC Controller
Manufacturer
Linear Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC3805EDD
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3805EDD
Manufacturer:
LINEAR
Quantity:
20 000
Part Number:
LTC3805EDD#PBF
Manufacturer:
LT
Quantity:
3 000
Part Number:
LTC3805EDD#PBF
Manufacturer:
LTNEAR
Quantity:
20 000
Company:
Part Number:
LTC3805EDD#PBF
Quantity:
1 315
Part Number:
LTC3805EDD#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3805EDD-5
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3805EDD-5#PBF/IDD
Manufacturer:
LT
Quantity:
397
Company:
Part Number:
LTC3805EDD-5#TRPBF
Quantity:
1 445
Part Number:
LTC3805EMSE
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3805EMSE
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3805EMSE-5
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC3805EMSE-5#TRPBF
Quantity:
5 300
www.datasheet4u.com
LTC3805
OPERATION
First, consider operation without overcurrent protection.
For some maximum converter output current, the voltage
on the I
This corresponds to a 100mV limit on the voltage at the
I
duty cycle is reduced as the output voltage sags. However,
the peak current in the external MOSFET is limited by the
100mV threshold at the I
As the output current is increased further, eventually,
the duty cycle is reduced to the 6% minimum. Since the
external MOSFET is always turned on for this minimum
amount of time, the current comparator no longer limits
the current through the external MOSFET based on the
100mV threshold. If the output current continues to in-
crease, the current through the MOSFET could rise to a
level that would damage the converter.
To prevent damage, the overcurrent pin OC is also
connected to the current sense resistor, and a fault is
triggered if the voltage on the OC pin exceeds 100mV. To
protect itself, the converter stops operating as described
in the next section. External resistors can be used to ad-
just the overcurrent threshold to voltages higher or lower
than 100mV as described in the Applications Information
section.
Soft-Start and Fault Timeout Operation
The soft-start and fault timeout of the LTC3805 uses either
a fi xed internal timer or an external timer programmed
by a capacitor from the SSFLT pin to GND. The internal
soft-start and fault timeout times are minimums and can
be increased by placing a capacitor from the SSFLT pin
to GND. Operation is shown in Figure 1.
Leave the SSFLT pin open to use the internal soft-start and
fault timeout. The internal soft-start is complete in about
1.8ms. In the event of an overcurrent as detected by the
OC pin exceeding 100mV, the LTC3805 shuts down and
an internal timing circuit waits for a fault timeout of about
4.25ms and then restarts the converter.
10
SENSE
pin. As the output current is further increased, the
TH
pin rises to and is clamped at approximately 1.9V.
SENSE
pin.
Add a capacitor C
both the soft-start time and the time for fault timeout. Dur-
ing soft-start, C
the LTC3805 comes out of shutdown, the LTC3805 quickly
charges C
switching. From that point, GATE continues switching with
increasing duty cycle until the SSFLT pin reaches about
2.25V at which point soft-start is over and closed-loop
regulation begins. The voltage on the SSFLT pin addition-
ally further charges to about 4.75V.
C
fault. After a fault, C
4.75V to about 0.7V by a 2μA current. When the voltage
on the SSFLT pin reaches 0.7V the converter attempts to
restart. More detail on programming the external soft-start
fault timeout is described in the Applications Information
section.
Powering the LTC3805
A built-in shunt regulator from the V
the voltage on the V
as the shunt regulator is not forced to sink more than
25mA. The shunt regulator is always active, even when
the LTC3805 is in shutdown, since it serves the vital func-
tion of protecting the V
regulator permits the use of a wide variety of powering
schemes for the LTC3805 even from high voltage sources
that exceed the LTC3805’s absolute maximum ratings.
Further details on powering schemes are described in the
Applications Information section.
Adjustable Slope Compensation
The LTC3805 injects a 10μA peak current ramp out of
its I
external resistor, for slope compensation in designs that
require it. This current ramp is approximately linear and
begins at zero current at 6% duty cycle, reaching peak
current at 80% duty cycle. Additional details are provided
in the Applications Information section.
SS
SENSE
also performs the timeout function in the event of a
SS
pin which can be used, in conjunction with an
to about 0.7V at which point GATE begins
SS
SS
is charged with a 6μA current. When
from the SSFLT pin to GND to increase
CC
SS
CC
pin to approximately 9.5V as long
is slowly discharged from about
pin from overvoltage. The shunt
CC
pin to GND limits
3805fb

Related parts for LTC3805