SPECIFICATIONS
Contacts
Coil (at 20 C
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
TYPICAL
APPLICATIONS
1. Home appliances
2. Office equipment
110
1
2
3
4
5
6
7
8
Type
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Rating
(resistive)
Expected
life (min.
operations)
Nominal operating power
Measurement at same location as "initial breakdown voltage" section
Detection current: 10 mA
Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
www.DataSheet4U.com
• Air conditioners
• Microwave ovens
• TV sets
• Heaters
• Stereo
• Copiers
• Vending machines
1.969
Nominal
switching capacity
Max. switching
power
Max. switching
voltage
Max. switching
current
Mechanical
(at 180 cpm)
Electrical
(at 20 cpm)
50
68
F)
DC coil type
33
1.299
1.92 W
2 10
mm
35.8
1.409
10
277 V
8,310
30 A
30 A
AC
VA
DC coil type
1a
5
(1a: 30 A 277 V AC, 2a: 25 A 277 V AC)
5
inch
(1a: 30 A 250 V AC, 2a: 20 A 250 V AC)
10
277 V AC, 30 V DC
7
TV-15, 30 AMP (1 Form A)
Power Relay
277 V
6,925
See Coil data (next page)
25 A
25 A
AC
VA
2a
Silver alloy
100 m
FEATURES
• High contact capacity with superior inrush current characteristics;
• Excellent high heat-resistance;
• High dielectric strength: 10,000 V surge Conforming to VDE0806
ORDERING INFORMATION
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
* PC board terminal are available only for 1 Form A type of DC coil voltage.
UL/CSA, TÜV approved type is standard.
AC coil type
Contact arrangement
(Insulation gap: 8 mm
TV rating
277 V
8,310
Rating
30 A
30 A
AC
VA
1a
AC coil type
1a: 1 Form A
2a: 2 Form A
5 10
277 V
6,925
6
25 A
25 A
30 A 277 V AC
AC
VA
2a
1 Form A
TV-15
HE
Characteristics
N: 70% of nominal
Maximum operating speed
Initial insulation resistance*
Initial
breakdown
voltage*
Surge voltage between coil
and contact*
Operate time*
(at nominal voltage)
Release time*
(at nominal voltage)
Temperature rise, max.
(resistive load)(at 55 C)
Shock resistance
Vibration resistance
Conditions for opera-
tion, transport and
storage*
and condensing at low
temperature)
Unit weight
1a
Pick-up voltage
.315
voltage
25 A 277 V AC
inch) VDE, TÜV also approved
2 Form A
2
8
(Not freezing
TV-10
N
3
Between open contacts
Between contacts and
coil
Between contact sets
(2a)
4
4
HE RELAYS
Nil: Plug-in terminal type
S: Screw terminal type
SW: Screw terminal type
Q: NEMA terminal type
P: PC board terminal type*
Functional*
Destructive*
Functional*
Destructive
Ambient
temp.
Humidity
Air pressure
S
1
(wide pitch)
Terminals
5
7
6
DC12
at double amplitude of 1.5 mm
Approx. 5 ms Approx. 20 ms
at double amplitude of 1 mm
DC coil type
Min. 1,000 M
2,000 Vrms for 1 min.
5,000 Vrms for 1 min.
4,000 Vrms for 1 min.
60 C
Approx. 90 g
980 m/s
–58 F to +131 F
–50 C to +55 C
Approx. 20 ms
98 m/s
5 to 85% R.H.
Min. 10,000 V
86 to 106 kPa
(Plug-in type)
V
10 to 55 Hz
10 to 55 Hz
20 cpm
DC: 6, 12, 24, 48,
AC: 12, 24, 48,
2
2
Coil voltage
{10 G}
{100 G}
at 500 V DC
120, 240 V
110 V
AC coil type
3.17 oz
VDE