NJU9214FG1 New Japan Radio Co., Ltd., NJU9214FG1 Datasheet - Page 18

no-image

NJU9214FG1

Manufacturer Part Number
NJU9214FG1
Description
4 3/4 DIGIT Single Chip Digital Multimeter LSI
Manufacturer
New Japan Radio Co., Ltd.
Datasheet
NJU9214
Measured value
Measured value
Measured value
[ Ex.3 ] In DCV400mV range, when overflow is occurred on the positive voltage side by 401mV input.
[ Ex.4 ] In DCV400mV range, when overflow is occurred on the negative voltage side by -401mV input.
[ Ex.5 ] In DCV400mV range, when the battery life detector warns under the condition of Ex.1.
[ Ex.6 ] In ACA400mA range, when the following current is measured.
[ Ex.7 ] In resistance 400k
[ Ex.8 ] In frequency 10kHz range, when the following frequency is measured.
[ Ex.9 ] In tachometer 6000rpm range, the following revolution is measured.
Format pattern
Format pattern
Measured value
Format pattern
Measured value
Format pattern
Measured value
Format pattern
Measured value
Format pattern
Format pattern
DCV, A=+
DCV, A=-
DCV, A=+100.01m, B[CR]
ACA, A=+040.00m, □[CR]
OHM, A=+100.10k, □[CR]
FRQ, A=+005.35k, □[CR]
rpm, A=+02500□, □[CR]
"
. " shows overflow, "-" shows overflow on the negative side.
"
overflow on the "-" side
100.01mV
40.00mA
100.10k
5.35kHz
2500rpm
. m, □[CR]
. m, □[CR]
. " shows overflow, "+" shows overflow on the positive side.
overflow on the " + " side
range, when the following resistance is measured.
Battery life detector

Related parts for NJU9214FG1