(a) CN1(Interface signal)
(b) CN2 (BACKLIGHT)
CPT Confidential
*
[Note]: VBLH-VBLL=VL
4.Connector Interface PIN & Function
Outlet connector: FI-XB30SL-HF10 (JAE)
Link connector: FI-X30H (JAE, Link Type )
(Note) DDC: Display Data Requirements
Backlight-side connector: BHSR-02VS-1 (JST)
Inverter-side connector: SM02B-BHSS-1 (JST)
*3) Definition of the lamp life time:
*4) For keeping good lighting situation ,when design the inverter,it must be considered that the
*5) WL=IL x VL x 6。(IL=6mA,Ta=25℃)
Pin No.
(Note)Refer to page6、7、8、9之 Data Mapping
a. Luminance (L) under 50% of specification starting lamp voltage
b. Starting Lamp Voltage: over130% of the initial value. Ta=25℃
voltage large than starting lamp voltage.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
2
3
4
5
6
7
8
9
Pin No.
1
2
DATA_EDID
CLK_
RCLKN
SYMBOL
RCLKP
V_
BIST
R0N
R1N
R2N
R0P
R1P
R2P
Vss
Vin
Vin
Vss
Vss
Vss
Vss
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
EDID
EDID
Symbol
CTH
CTL
Ground
+3.3V Power
+3.3V Power
DDC 3.3V Power
Build in self-test pattern
DDC Clock
DDC Data
minus signal of channel 0(LVDS)
plus signal of channel 0(LVDS)
Ground
minus signal of channel 1(LVDS)
plus signal of channel 1(LVDS)
Ground
minus signal of channel 2(LVDS)
plus signal of channel 2(LVDS)
Ground
minus signal of clock channel (LVDS)
plus signal of clock channel (LVDS)
Ground
No connect
VCOM test provided , but customer-end unused (open)
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
10/21
VBLH (High)
VBLL (Low)
www.DataSheet.net/
Function
FUNCTION
CHUNGHWA PICTURES TUBES, LTD.,
0 Normal operation
1 Test pattern mode
CLAA154WB04-STUDIO-
20061205
www.yslcd.com.tw
Datasheet pdf - http://www.DataSheet4U.co.kr/