SN74LS248 Motorola, SN74LS248 Datasheet
SN74LS248
Related parts for SN74LS248
SN74LS248 Summary of contents
Page 1
BCD-TO-SEVEN-SEGMENT DECODERS/DRIVERS The SN54/74LS247 thru SN54/74LS249 are BCD-to-Seven-Segment Decoder/Drivers. The LS247 and LS248 are functionally and electrically identical to the LS47 and LS48 with the same pinout configuration. The LS249 is a 16-pin version of the 14-pin LS49 and includes ...
Page 2
... B C LAMP TEST OUT IN PUT PUT INPUTS INPUTS ALL CIRCUIT TYPES FEATURE LAMP INTENSITY MODULATION CAPABILITY TYPE ACTIVE LEVEL SN54LS247 SN54LS248 SN54LS249 SN74LS247 SN74LS248 SN74LS249 LS247 (7) INPUT A (1) INPUT B (2) INPUT C (6) INPUT D BI/RBO BLANKING (4) INPUT OR RIPPLE BLANKING OUTPUT (3) LAMP TEST ...
Page 3
SN54/74LS247 SN54/74LS248 SN54/74LS249 DECIMAL INPUTS OR OR FUNCTION FUNCTION LT RBI ...
Page 4
GUARANTEED OPERATING RANGES Symbol Parameter V CC Supply Voltage T A Operating Ambient Temperature Range I OH Output Current — High BI / RBO I OL Output Current — Low BI / RBO V O(off) Off-State Output Voltage a – ...
Page 5
GUARANTEED OPERATING RANGES Symbol Parameter V CC Supply Voltage T A Operating Ambient Temperature Range I OH Output Current — High BI / RBO OH Output Current — High a – g Output Current — Low BI / RBO I ...
Page 6
GUARANTEED OPERATING RANGES Symbol Parameter V CC Supply Voltage T A Operating Ambient Temperature Range I OH Output Current — High BI / RBO I OL Output Current — Low BI / RBO Output Current — Low BI / RBO ...
Page 7
G - 0.25 (0.010 - SEATING -T- PLANE 0.25 (0.010) ...
Page 8
... Motorola reserves the right to make changes without further notice to any products herein. Motorola makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters can and do vary in different applications. All operating parameters, including “ ...