Page 1
... Safety for mains-operated electronic and related household apparatus Order Instruction Ordering Code 1) K3010P/ K3010PG 1) K3011P/ K3011PG 1) K3012P/ K3012PG Leadform 10.16 mm not marked on the body Document Number 83504 Rev. A4, 13–Sep–99 highest safety 300 V 600 V Note: Pin 5 must not be connected CTR Ranking < ...
Page 2
... K3010P(G) Series Vishay Telefunken Features Approvals: D BSI 41003 60095 (BS 415 60950 (BS 7002), Certificate number 7081 and 7402 D FIMKO (SETI): EN 60950, Certificate number 12398 D Underwriters Laboratory (UL) 1577 recognized, file number E-76222 D VDE 0884, Certificate number 94778 VDE 0884 related features: ...
Page 3
... Symbol Min 250 DRM (dv/dt (dv/dt) 0.1 crq Type Symbol W = 150 K3010P( K3011P( K3012P( 10813 and dv/dt cr crp K3010P(G) Series Vishay Telefunken Typ. Max. Unit 1.25 1 Typ. Max. Unit V 1 ...
Page 4
... K3010P(G) Series Vishay Telefunken dv/dt Highest value of the “rate of rise of off-state voltage” which does not cause any switching from the cr off-state to the on-state dv/dt Highest value of the “rate of rise of communicating voltage” which does not switch on the device again, ...
Page 5
... C T amb (construction test only) V IOTM IOWM V IORM 0 125 150 t 1 13930 Figure 5. Test pulse diagram for sample test according to K3010P(G) Series Vishay Telefunken Value Unit 130 mA Value Unit 600 mW Value Unit 6 kV ° C 150 Min. Typ. Max. Unit 1.6 ...
Page 6
... K3010P(G) Series Vishay Telefunken Typical Characteristics 400 Coupled device 300 Phototransistor 200 IR-diode 100 – Ambient Temperature ( 11701 amb Figure 6. Total Power Dissipation vs. Ambient Temperature 1000.0 100.0 10.0 1.0 0.1 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 V – Forward Voltage ( 11862 F Figure 7. Forward Current vs. Forward Voltage 1 ...
Page 7
... Type XXXXXX 918 Date Code 0884 (YM Coupling Company System Logo Indicator Figure 12. Marking example Dimensions of K301. Document Number 83504 Rev. A4, 13–Sep–99 Production Location Safety Logo 15090 K3010P(G) Series Vishay Telefunken 14771 www.vishay.de FaxBack +1-408-970-5600 7 (9) ...
Page 8
... K3010P(G) Series Vishay Telefunken Dimensions of K301 www.vishay.de FaxBack +1-408-970-5600 8 (9) 14770 Document Number 83504 Rev. A4, 13–Sep–99 ...
Page 9
... Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use ...