SDS150 XP Power Limited, SDS150 Datasheet

no-image

SDS150

Manufacturer Part Number
SDS150
Description
AC-DC Power Supplies
Manufacturer
XP Power Limited
Datasheet
www.DataSheet4U.com
150 Watts
SDS150 Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • <0.40 mA at 115 VAC
Input Protection
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 112-132%, recycle input to reset
Overload Protection
Short Circuit Protection • Trip & restart (Hiccup mode),
Temperature
Coefficient
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 2.0 A at 115 VAC
• 20 A at 115 VAC
• >0.95
• 3.15 A on board fuse
• See table
• ±5%
• ±1%
• No minimum load required
• 2 s max
• 2 ms typical
• >16 ms
• 1% max, ±0.5% typical
• 5% max, ±3.0% typical
• 4% max deviation, recovery to within 1%
• 1% pk-pk max
• 110-150% with auto recovery
• 0.04%/°C
1.0 A at 230 VAC
63 A at 230 VAC
<0.75 mA at 230 VAC
in 500 µs for a 50% load change
auto recovery
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
Cooling
Operating Humidity
Storage Temperature
Vibration
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
3” x 5” Footprint
Fits 1U Applications
Convection-cooled
Open Frame & U-Channel Versions
Optional Power Fail Detect Signal
Optional Low Temperature Operation
Up to 90% Efficiency
• 88% typical, 90% max
• 3000 VAC Input to Output
• PWM 60 kHz typical, PFC 100 kHz typical
• 6.9 W/In
• Power Fail Detect = TTL low (option)
• >100 kHrs per MIL-HDBK-217F
• Convection-cooled
• 5-95% RH, non-condensing
• -40 °C to +85 °C
• 2 g on 3 axes
• EN55022, FCC Part 15, level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 70% U
• EN60950-1, UL60950-1, CSA60950-1
1500 VAC Input to Ground
500 VDC Output to Ground
load at +50 °C to 50% load at +70 °C,
low temperature option ‘-L’ -40 °C
40% U
Perf Criteria A, B, B
per cUL, CE Mark LVD
T
3
for 100 ms, <5% U
for open frame version
xppower.com
T
for 10 ms,
T
for 5000 ms

Related parts for SDS150

SDS150 Summary of contents

Page 1

... Watts www.DataSheet4U.com SDS150 Series Specification Input Input Voltage • 90-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz Input Current • 2 115 VAC 1 230 VAC Inrush Current • 115 VAC 230 VAC Power Factor • >0.95 Earth Leakage Current • <0. 115 VAC < ...

Page 2

... For optional 2 pin Molex input, add suffix ‘-D’ to model number. Example SDS150PS12-D. 3. For non-standard voltages contact sales office. 4. For optional Power Fail Detect signal (PFD), add suffix ‘-P’ to model number . Example: SDS150PS48B-P. 5. For optional PCB only version, delete suffix ‘B’ from model number. Example SDS150PS48. ...

Related keywords