SDS120 XP Power Limited, SDS120 Datasheet

no-image

SDS120

Manufacturer Part Number
SDS120
Description
AC-DC Power Supplies
Manufacturer
XP Power Limited
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SDS1205TTEB500Y
Manufacturer:
KOA SPEER
Quantity:
20 000
Part Number:
SDS1206-470Y
Manufacturer:
MOLEX
Quantity:
38 361
Part Number:
SDS1206TTEB121Y
Manufacturer:
KOA SPEER
Quantity:
20 000
Part Number:
SDS1206TTEB150M
Quantity:
78
Part Number:
SDS1206TTEB150M
Manufacturer:
KOA SPEER
Quantity:
20 000
Part Number:
SDS1206TTEB221K
Manufacturer:
KOA SPEER
Quantity:
20 000
Part Number:
SDS1206TTEB270Y
Manufacturer:
KOA SPEER
Quantity:
20 000
www.DataSheet4U.com
120 Watts
SDS120 Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • <0.30 mA at 115 VAC
Input Protection
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 112-132% V1 only, recycle input to reset
Overload Protection
Short Circuit Protection • Trip & restart (Hiccup mode),
Temperature
Coefficient
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 1.7 A at 115 VAC
• <30 A at 115 VAC
• 0.97 typical
• 3.15 A on board fuse
• See table
• ±5% output 1 only (3.3 V variant ±10%)
• Single output models: ±1%
• No minimum load required for single
• 2 s max
• 2 ms
• >16 ms
• 1% maximum, ±0.5% typical
• 5% maximum, ±3.0% typical
• 4% max deviation, recovery to within
• 1% pk-pk typical, 20 MHz BW
• All outputs: 110-150% with auto recovery
• 0.04%/°C
1.0 A at 230 VAC
<55 A at 230 VAC
<0.75 mA at 230 VAC
Multi-output models: ±5%
output models. For multi-output models
see table.
1% in 4 ms for a 50% load change
(primary power limit)
auto recovery
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
Cooling
Operating Humidity
Storage Temperature
Vibration
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
Single, Dual & Triple Outputs
Convection-cooled
3” x 5” Footprint
High Efficiency to 85%
Open Frame, U-Channel & Covered Versions
Low Temperature Option
Optional Power Fail Detect Signal
• 80% typical, 85% max,
• 3000 VAC Input to Output
• PFC 100 kHz, PWM 67 kHz
• 4.87 W/In
• Power Fail Detect = TTL active low,
• >100 kHrs per MIL-HDBK-217F
• Convection-cooled
• 5-95% RH, non-condensing
• -40 °C to +85 °C
• 2 g on 3 axes
• EN55022, CISPR22 and FCC, part 15
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 30% 10 ms,
• EN60950-1, UL60950-1,
combined AC and DC OK signal (option)
load at +50 °C to 50% load at +70 °C,
low temperature option ‘-L’ -40 °C
level B conducted
60% 100 ms, >95% 5000 ms
Perf Criteria A, B, B
CSA60950-1 per cUL, CE Mark LVD
230 VAC 100% load
1500 VAC Input to Ground
500 VAC Output to Ground
3
xppower.com

Related parts for SDS120

SDS120 Summary of contents

Page 1

... Watts www.DataSheet4U.com SDS120 Series Specification Input Input Voltage • 90-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz Input Current • 1 115 VAC 1 230 VAC Inrush Current • < 115 VAC < 230 VAC Power Factor • 0.97 typical Earth Leakage Current • <0. 115 VAC < ...

Page 2

... I/P connector P1 mates with Molex housing 09-50-3051 & Molex 2878 series crimp terminal. 3. O/P P2 mates with Molex housing 09-50-3131 & Molex 2878 series crimp terminal. 4. For optional cover kit order part number SDS120 COVER†, to receive unit with cover fitted 0.25 (6.4) add suffix ‘C’ to model number (overall height is 1.73 (44.0)). ...

Related keywords