SY10E136JC Micrel Inc, SY10E136JC Datasheet

IC COUNTER UP/DOWN 6-BIT 28-PLCC

SY10E136JC

Manufacturer Part Number
SY10E136JC
Description
IC COUNTER UP/DOWN 6-BIT 28-PLCC
Manufacturer
Micrel Inc
Series
10Er
Datasheet

Specifications of SY10E136JC

Logic Type
Binary Counter
Direction
Up, Down
Number Of Elements
1
Number Of Bits Per Element
6
Reset
Asynchronous
Timing
Synchronous
Count Rate
650MHz
Trigger Type
Positive Edge
Voltage - Supply
4.2 V ~ 5.5 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-LCC (J-Lead)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SY10E136JC
Manufacturer:
MAXIM
Quantity:
340
Part Number:
SY10E136JC
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
SY10E136JC
Manufacturer:
SYNERGY
Quantity:
1 258
Part Number:
SY10E136JC
Manufacturer:
ST
0
Part Number:
SY10E136JC
Manufacturer:
SYNERGY
Quantity:
20 000
Part Number:
SY10E136JC TR
Manufacturer:
Micrel Inc
Quantity:
10 000
Micrel, Inc.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
D
Q
S
MR
CLK
C
CL
C
CL
V
FEATURES
PIN NAMES
550MHz count frequency
Extended 100E V
Look-ahead-carry input and output
Fully synchronous up and down counting
Asynchronous Master Reset
Internal 75K input pull-down resistors
Available in 28-pin PLCC package
1
CCO
0
OUT
IN
0
, S
–D
–Q
OUT
IN
2
5
, C
Pin
5
OUT
EE
Preset Data Inputs
Differential Data Outputs
Mode Control Pins
Master Reset
Clock Input
Carry Out Output (Active LOW)
Look-Ahead-Carry Output
Carry-In Input (Active LOW)
Look-Ahead-Carry Input
V
range of –4.2V to –5.5V
CC
to Output
Function
6-BIT UNIVERSAL
UP/DOWN COUNTER
1
cascadable universal counters. These devices generate
a look-ahead-carry output and accept a look-ahead-carry
input. These two features allow for the cascading of
multiple E136s for wider bit width counters that operate
at very nearly the same frequency as the stand-alone
counter.
one count before the E136 reaches terminal count. The
C
the counter reaches terminal count. For more information
on utilizing the look-ahead-carry features of the device,
please refer to the applications section of this data sheet.
The differential C
programmable divider and self-stopping counter
applications.
designs, the E136 carry-out and look-ahead-carry-out
signals are registered on chip. This design alleviates the
glitch problem seen on many counters where the carry-
out signals are merely gated. Because of this architecture,
there are some minor functional differences between the
E136 and H136 counters. The user, regardless of
familiarity with the H136, should read this data sheet
carefully. Note specifically (see block diagram) the
operation of the carry-out outputs and the look-ahead-
carry-in input when utilizing the Master Reset.
LOW via an input pulldown resistor. The Master Reset is
an asynchronous signal which, when asserted, will force
the Q outputs LOW.
function properly. In fact, if these outputs will not be
used in a system, it is recommended that they be left
open to save power and minimize noise. This practice
will minimize switching noise which can reduce the
maximum count frequency of the device, or significantly
reduce margins against other noise in the system.
OUT
DESCRIPTION
The SY10/100E136 are 6-bit synchronous, presettable,
The CL
Unlike the H136 and other similar universal counter
When left open, all of the input pins will be pulled
The Q outputs need not be terminated for the E136 to
output will pulse LOW for one clock cycle when
OUT
output will pulse LOW for one clock cycle
OUT
output facilitates the E136's use in
Rev.: F
Issue Date: March 2006
SY100E136
SY10E136
SY100E136
Amendment: 0
SY10E136

Related parts for SY10E136JC

SY10E136JC Summary of contents

Page 1

Micrel, Inc. FEATURES 550MHz count frequency Extended 100E V range of –4.2V to –5.5V EE Look-ahead-carry input and output Fully synchronous up and down counting Asynchronous Master Reset Internal 75K input pull-down resistors Available in 28-pin PLCC package PIN NAMES ...

Page 2

... SY100E136JZTR J28-1 Notes: 1. Contact factory for die availability. Dice are guaranteed Tape and Reel. 3. Pb-Free package is recommended for new designs. 2 Operating Package Range Marking Commercial SY10E136JC Commercial SY10E136JC Commercial SY100E136JC Commercial SY100E136JC Commercial SY10E136JC Commercial SY10E136JC Commercial SY100E136JC Commercial SY100E136JC Commercial ...

Page 3

Micrel, Inc. (1) BLOCK DIAGRAM LOGIC DIAGRAM Note: 1. This diagram is provided for understanding of logic operation only. It should not be used for propagation delays as many gate functions are achieved internally without incurring a full gate delay. ...

Page 4

Micrel, Inc. (1) LOGIC DIAGRAM TRUTH TABLE Note: 1. Expanded truth table included ...

Page 5

Micrel, Inc. DC ELECTRICAL CHARACTERISTICS LOGIC DIAGRAM (Min (Max.); Symbol Parameter I Input HIGH Current IH I Power Supply Current EE 10E 100E LOGIC DIAGRAM AC ELECTRICAL CHARACTERISTICS V = ...

Page 6

Micrel, Inc. APPLICATIONS INFORMATION LOGIC DIAGRAM Overview The SY10E/100E136 are 6-bit synchronous, presettable, cascadable universal counters. Using the S pins, the user can select between preset, count up, count down and hold count. The Master Reset pin will reset the ...

Page 7

Micrel, Inc CLK Figure 2. Look-Ahead-Carry Input Structure Note from the waveforms that the look-ahead-carry output (CL ) pulses low one clock pulse before the counter OUT reaches terminal count. Also note that both ...

Page 8

Micrel, Inc. LOAD CLOCK S1 C OUT The exercise of building a programmable divider then becomes simply determining what value to load into the counter to accomplish the desired division. Since the load operation requires a clock pulse, to divide ...

Page 9

Micrel, Inc. 28-PIN PLCC (J28-1) MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA + 1 (408) 944-0800 TEL The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is ...