... Line and load regulation performance has been improved as well. Additionally, the SG117A reference voltage is guaranteed not to exceed 2% when operating over the full load, line and power dissipation conditions. The SG117A adjustable regulators offer an improved solution for all positive voltage regulator requirements with load currents ...
Page 2
... Note 3. These ratings are applicable for junction temperatures of less than 150°C. ELECTRICAL CHARACTERISTICS (Unless otherwise specified, these specifications apply over full operating ambient temperatures for SG117A/SG117 with -55°C ≤ T SG217 with -25°C ≤ T ≤ 150°C, SG 317A/SG317 with 0°C ≤ and L packages) ...
Page 3
... OUT ) ≤ 15V ( OUT Packages T, L Packages ( 40V 25°C IN OUT Packages T, L Packages T = 125° 25°C, 10Hz ≤ f ≤ 10KHz T (Note SG117A/SG117 SERIES SG117A/SG217A SG117/SG217 Min. Typ. Max. Min. Typ. Max. 3.5 5 3.5 5 1.5 2.2 1.5 2.2 0.5 0.8 0.5 0.8 0.3 0.4 0.3 0.4 0.15 0.2 0.15 0.2 1 ...
Page 4
... Rev 1.2 10/02 Copyright 1994 FIGURE 2. OUTPUT CURRENT VS. INPUT/OUTPUT DIFFERENTIAL FIGURE 5. REFERENCE VOLTAGE VS. TEMPERATURE FIGURE 8. RIPPLE REJECTION VS. FREQUENCY 4 SG117A/SG117 SERIES FIGURE 3. ADJUSTMENT CURRENT VS. TEMPERATURE FIGURE 6. QUISCENT CURRENT VS. INPUT/OUTPUT DIFFERENTIAL FIGURE 9. RIPPLE REJECTION VS. OUTPUT CURRENT L INFINITY Microelectronics Inc. 11861 Western Avenue ∞ ∞ ∞ ∞ ∞ Garden Grove, CA 92841 ...
Page 5
... Copyright 1994 FIGURE 11. LINE TRANSIENT RESPONSE FIGURE 14. LINE TRANSIENT RESPONSE FIGURE 16. OUTPUT VOLTAGE ERROR 5 SG117A/SG117 SERIES FIGURE 12. LOAD TRANSIENT RESPONSE FIGURE 15. LOAD TRANSIENT RESPONSE L INFINITY Microelectronics Inc. 11861 Western Avenue ∞ ∞ ∞ ∞ ∞ Garden Grove, CA 92841 (714) 898-8121 ∞ ∞ ∞ ∞ ∞ FAX: (714) 893-2570 ...
Page 6
... APPLICATION INFORMATION GENERAL The SG117A develops a 1.25V reference voltage between the output and the adjustable terminal (see Figure 1). By placing a resistor, R between these two terminals, a constant current is 1 caused to flow through R and down through R 1 output voltage, Normally this current is the specified minimum load current of 5mA or 10mA ...
Page 7
... FIGURE 20 - REMOTE SENSING FIGURE 21 - IMPROVING RIPPLE REJECTION LOAD REGULATION Because the SG117A is a three-terminal device not possible to provide true remote load sensing. Load regulation will be limited by the resistance of the wire connecting the regulator to the load. For the data sheet specification, regulation is measured at the bottom of the package ...