RE46C126 R&E International, Inc., RE46C126 Datasheet
![no-image](/images/no-image-200.jpg)
RE46C126
Related parts for RE46C126
RE46C126 Summary of contents
Page 1
... RE46C126 CMOS Ionization Smoke Detector ASIC with Interconnect Product Specification General Description The RE46C126 is low power CMOS ionization type smoke detector IC. With few external components this circuit will provide all the required features for an ionization type smoke detector. An internal oscillator strobes power to the smoke detection circuitry for 10 ...
Page 2
... Units 4.5 6 6.2 4 4.5 2 -0.75 pA -1.50 pA -50 uA 0. 100 uA 150 6 7.2 7 kΩ 90 130 170 mV E-mail: rande@randeint.com DS-RE46C126-010907 ...
Page 3
... IO as Input, No Local Alarm No Local Alarm input, From IO 2 active to Horn Active Facsimile 610.992.0734 R&E International Limits Min Typ Max Units 1.34 1. 37.5 41.5 45.8 mS 9.1 10.5 12.9 mS 9.1 10.5 12 1.1 S 141 166 190 mS 9.4 10.5 12 1.34 1.67 2 450 mS .450 2.2 S E-mail: rande@randeint.com DS-RE46C126-010907 ...
Page 4
... RE46C126 CMOS Ionization Smoke Detector ASIC with Interconnect Product Specification Telephone 610.992.0727 Page This datasheet contains PROPRIETARY and CONFIDENTIAL information. Functional Block Diagram Figure 1 Facsimile 610.992.0734 R&E International E-mail: rande@randeint.com DS-RE46C126-010907 ...
Page 5
... Testing - By holding pin 12 (OSCAP) low the internal power strobe is active and pin1 (DETCOMP) can be used to check for smoke. Please refer to the timing diagrams. Telephone 610.992.0727 Page This datasheet contains PROPRIETARY and CONFIDENTIAL information. Facsimile 610.992.0734 R&E International E-mail: rande@randeint.com DS-RE46C126-010907 ...
Page 6
... C2 should be located as close as possible to the device power pins. 3. Route the pin 8 PC board trace away from pin 7 to avoid coupling. Telephone 610.992.0727 Page This datasheet contains PROPRIETARY and CONFIDENTIAL information. Typical Application Figure 2 Facsimile 610.992.0734 R&E International E-mail: rande@randeint.com DS-RE46C126-010907 ...
Page 7
... See Figure Below for Complete Horn Cycle T IODLY2 Horn pattern not self completing for external alarm Facsimile 610.992.0734 R&E International Alarm; Low Battery No Alarm; Low Battery Pin 15 > Pin 13 Low Battery Warning Chirp T IODMP LED supressed in remote alarm mode E-mail: rande@randeint.com DS-RE46C126-010907 ...
Page 8
... A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system affect its safety or effectiveness. Telephone 610.992.0727 Page This datasheet contains PROPRIETARY and CONFIDENTIAL information. Facsimile 610.992.0734 R&E International E-mail: rande@randeint.com DS-RE46C126-010907 ...