CMA6090E Crydom Corporation, CMA6090E Datasheet

no-image

CMA6090E

Manufacturer Part Number
CMA6090E
Description
Cmd / Cma60 Series
Manufacturer
Crydom Corporation
Datasheet
Maximum I
For Contact information visit our web
site.
CMD / CMA60 Series
PRODUCT SELECTION
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Control Voltage
4-32 VDC
90-140 Vrms
18-36 Vrms
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current (3) [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Minimum Power Factor (with Maximum Load)
2
t for Fusing (8.3 msec) [A
CMA6025E
CMD6025
CMA6025
25A
2
sec]
CMA6050E
CMD6050
CMA6050
• Ratings from 25A to 125A @ 48-660 VAC
• SCR output for heavy industrial loads
• AC or DC control
• LED input status indicator
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
• IP20 touch-safe housing
• Standard box-clamp connections
• Ratings from 25A to 125A @ 48-660 VAC
50A
www.crydom.com
48-660
1200
0.15
1.02
500
250
260
1.0
1.6
0.5
25
CMA6075E
CMD6075
CMA6075
75A
48-660
1200
1620
0.15
0.63
500
625
1.0
1.6
0.5
50
CMA6090E
CMD6090
CMA6090
90A
48-660
1200
1000
4150
0.25
0.31
500
1.0
1.6
0.5
75
Specifications subject to change without notice.
48-660
1200
1200
6000
0.25
0.28
500
CMA60110E
1.0
1.6
0.5
90
CMD60110
CMA60110
110A
48-660
©2008 Crydom, Inc.
1200
1500
9340
0.25
0.25
500
110
1.0
1.6
0.5
CMA60125E
CMD60125
CMA60125
125A
48-660
12700
0.025
1200
1750
0.22
500
125
1.0
1.6
0.5

Related parts for CMA6090E

CMA6090E Summary of contents

Page 1

... CMA6050 CMA6075 CMA6050E CMA6075E 48-660 48-660 1200 1200 1.0 1.0 500 500 25 50 0.15 0.15 250 625 1.6 1.6 1.02 0.63 260 1620 0.5 0.5 www.crydom.com 90A 110A CMD6090 CMD60110 CMA6090 CMA60110 CMA6090E CMA60110E 48-660 48-660 48-660 1200 1200 1200 1.0 1.0 1.0 500 500 500 75 90 110 0.25 0.25 0.25 1000 1200 1500 1.6 1.6 1.6 0.31 0.28 0.25 4150 6000 9340 0.5 ...

Page 2

INPUT SPECIFICATIONS (1) Description Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Minimum Turn-Off Voltage Maximum Input Current Typical Input current Maximum Turn-On Time [msec] (4) Maximum Turn-Off Time [msec] GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation ...

Page 3

MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS UL E116949, E116950 CSA LR 81689 VDE 126921 UG (up to 90A models only) For Contact information visit our web site. www.crydom.com R ev. 062508 ©2008 Crydom, Inc. Specifications subject to change without ...

Page 4

For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice. ...

Page 5

ANNEX - ENVIROMENTAL INFORMATION For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice. ...

Related keywords