BT136E UTC, BT136E Datasheet

no-image

BT136E

Manufacturer Part Number
BT136E
Description
TRIACS
Manufacturer
UTC
Datasheet
UTC BT136E
TRIACS
DESCRIPTION
Passivated triacs in a plastic envelope, intended for use in
applications requiring high bidirectional transient and blocking
voltage capability and high thermal cycling performance. Typical
applications include motor control, industrial and domestic
lighting, heating and static switching.
SYMBOL
ABSOLUTE MAXIMUM RATINGS
Repetitive peak off-state voltages
RMS on-state current
full sine wave; T
Non-repetitive peak on-state current
(Full sine wave; T
I
Repetitive rate of rise of on-state current after triggering
I
Peak gate voltage
Peak gate current
Peak gate power
Average gate power (over any 20 ms period)
Storage temperature
Operating junction temperature
*Although not recommended, off-state voltages up to 800V may be applied without damage, but the traic may switch
to the on-state. The rate of rise of current should not exceed 3A/µs.
UTC
2
TM
t for fusing
= 6 A; I
G
= 0.2A;d
mb
t = 20ms
t = 16.7 ms
t = 10 ms
j
G
= 25 °C prior to surge)
≤107 °C
PARAMETER
IG
UNISONIC TECHNOLOGIES CO., LTD.
/dt = 0.2A/μs
MT2
MT1
T2+G+
T2+G-
T2-G-
T2-G+
BT136-600
BT136-800
www.DataSheet4U.com
SYMBOL
I
dI
P
V
T(RMS)
I
V
P
T
I
G(AV)
TSM
DRM
I
T
GM
T
GM
GM
2
stg
t
/dt
j
1
1:MT1
RATINGS
-40 ~ 150
600*
800
50
50
50
10
125
3.1
0.5
25
27
4
5
2
5
2:MT2
3:GATE
TO-220
TRIAC
QW-R401-005,A
UNIT
A/μs
A
W
W
V
A
A
V
A
2
s
1

Related parts for BT136E

BT136E Summary of contents

Page 1

... UTC BT136E TRIACS DESCRIPTION Passivated triacs in a plastic envelope, intended for use in applications requiring high bidirectional transient and blocking voltage capability and high thermal cycling performance. Typical applications include motor control, industrial and domestic lighting, heating and static switching. SYMBOL MT2 ...

Page 2

... UTC BT136E THERMAL RESISTANCES PARAMETER Thermal resistance Junction to mounting base Full cycle Half cycle Thermal resistance Junction to ambient (In free air) ELECTRICAL CHARACTERISTICS PARAMETER SYMBOL STATIC CHARACTERISTICS Gate trigger current Latching current Holding current On-state voltage Gate trigger voltage Off-state leakage current ...

Page 3

... UTC BT136E Ptot α 6 α IT(RMS)/A Fig.1. Maximum on-state dissipation,P on-state current,I where =conduction angle. α T(RMS) ITSM/A 1000 initial=25℃max 100 dI /dt limit T T2-G+ quadrant 10 10us 100us 1ms 10ms T/s Fig.2.Maximum Permissible non-repetitive peak ...

Page 4

... UTC BT136E I (Tj (25℃ T2+G+ 2.5 2 1.5 1 0 Tj/℃ Fig. 7.Normalised gate trigger Current I (Tj)/I (25℃),versus junction temperature (Tj (25℃ 2.5 2 1.5 1 0 Tj/℃ Fig.8.Normalised latching Current I versus junction temperature Tj I (Tj (25℃) ...

Page 5

... UTC BT136E UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury ...

Related keywords