PBL38621-2 Ericsson, PBL38621-2 Datasheet - Page 13

no-image

PBL38621-2

Manufacturer Part Number
PBL38621-2
Description
Subscriber Line Interface Circuit
Manufacturer
Ericsson
Datasheet
Figure 10. Programmable overhead voltage (POV). R
is energized, dc current flows and the
comparator input voltage reverses polar-
ity.
Figure 11 gives an example of a ring trip
detection network. This network is
applicable, when the ring voltage is
superimposed on V
ring lead of the two-wire port. The dc voltage
across sense resistor R
the ring trip comparator input DT and DR
via the network R
With the line on-hook (no dc current) DT is
more positive than DR and the DET output
will report logic level high, i.e. the detector
is not tripped. When the line goes off-hook,
while ringing, a dc current will flow through
the loop including sense resistor R
will cause input DT to become more
negative than input DR. This changes out-
put DET to logic level low, i.e. tripped
detector condition. The system controller
(or line card processor) responds by de-
energizing the ring relay, i.e. ring trip.
Complete filtering of the 20 Hz ac
component at terminal DT and DR is not
necessary. A toggling DET output can be
examined by a software routine to deter-
mine the duty cycle. When the DET output
is at logic level low for more than half the
time, off-hook condition is indicated.
1
, R
B
and is injected on the
2
, R
7
6
5
4
3
2
1
0
RT
0
3
, R
is monitored by
4
, C
1
and C
RT
and
10
2
.
Relay driver
The PBL 386 21/2 SLIC incorporates a ring
relay driver designed as open collector
(npn) with a current sinking capability of
50 mA. The drive transistor emitter is
connected to BGND. The relay driver has
an internal zener diode clamp for inductive
kick-back voltages.Care must be taken
when using the relay driver together with
relays that have high impedance.
Control Inputs
The PBL 386 21/2 SLIC has three digital
control inputs, C1, C2 and C3.
A decoder in the SLIC interprets the control
input condition and sets up the commanded
operating state.
C1 to C3 are internal pull-up inputs.
Open Circuit State
In the Open Circuit State the TIPX and
RINGX line drive amplifiers as well as other
circuit blocks are powered down. This
causes the SLIC to present a high
impedance to the line. Power dissipation is
at a minimum and no detectors are active.
20
L
= 600
R
OV
or .
30
(k )
40
Ringing State
The ring relay driver and the ring trip detector
are activated and the ring trip detector is
indicating off hook with a logic low level at
the detector output.
As the SLIC do not have any stand by state
the SLIC will remain in the active normal
state.
Active States
TIPX is the terminal closest to ground and
sources loop current while RINGX is the
more negative terminal and sinks loop
current. Vf signal transmission is normal.
The loop current or the ground key detector
is activated. The loop current detector is
indicating off hook with a logic low level and
the ground key detector is indicating active
ground key with a logic high level present at
the detector output.
50
60
PBL 386 21/2
13

Related parts for PBL38621-2