MIM-0KM2ASF Unity Opto Technology, MIM-0KM2ASF Datasheet - Page 4

no-image

MIM-0KM2ASF

Manufacturer Part Number
MIM-0KM2ASF
Description
INFRARED RECEIVER MODULE
Manufacturer
Unity Opto Technology
Datasheet
High temparature
High temp. & high humi.
Low temparature
Heat cycle
Dropping
NOTE 2. (electro-optical charactistics) shall be satisfied sfter leaving 2 hours in the normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
CAUTION ( When use and storage of this device )
Unity Opto Technology Co., Ltd.
Reliability
Inspection standard
Guarantee period and scope
Others
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
1.Among electrical characteristics , total number shall be inspected on items blow.
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
1.Guarantee period
2.Guarantee scope
, the soldering iron is connected to ground before using .
1-1 front distance between emitter & detector
1-3 H level output voltage
1-4 L level output voltage
covering the said problem .
1-2 Current consumption
One year after delivery to desired place .
A re-delivery of goods will be carried out if the cause of malfunction lies in our
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Test item
and destructions of appearance .(excepting deforms of terminals)
Ta=+60℃ Vcc=5.0 V
Ta=+40℃ 90%RH Vcc=5.0V
Ta= -10℃ Vcc=5.0V
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
-20℃(0.5H) ~ +75℃(0.5H) 20cycle
Test condition
t=240H
t=240H
t=240H
MIM-0KM2ASF
Standard
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
02/06/2001

Related parts for MIM-0KM2ASF