PIC16HV540 Microchip Technology, PIC16HV540 Datasheet - Page 13
PIC16HV540
Manufacturer Part Number
PIC16HV540
Description
Enhanced PIC16C54 EPROM-Based 8-Bit CMOS Microcontroller
Manufacturer
Microchip Technology
Datasheet
1.PIC16HV540.pdf
(85 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
PIC16HV540-04/P
Manufacturer:
Microchip
Quantity:
1 736
Company:
Part Number:
PIC16HV540-04/SO
Manufacturer:
Microchip
Quantity:
485
Company:
Part Number:
PIC16HV540-04I/P
Manufacturer:
MICROCHIP
Quantity:
664
Company:
Part Number:
PIC16HV540-04I/SO
Manufacturer:
Maxim
Quantity:
41
4.3
This register contains the arithmetic status of the ALU,
the RESET status, and the page preselect bits for pro-
gram memories larger than 512 words.
The STATUS register can be the destination for any
instruction, as with any other register. If the STATUS
register is the destination for an instruction that affects
the Z, DC or C bits, then the write to these three bits is
disabled. These bits are set or cleared according to the
device logic. Furthermore, the TO and PD bits are not
writable while the PCWUF bit is a read/write bit. There-
fore, the result of an instruction with the STATUS regis-
ter as destination may be different than intended.
REGISTER 4-1: STATUS REGISTER (ADDRESS:03h)
2000 Microchip Technology Inc.
bit7
bit 7:
bit 6-5:
bit 4:
bit 3:
bit 2:
bit 1:
bit 0:
PCWUF
R/W-0
STATUS Register
PCWUF: Pin Change Reset bit
1 = After Power-up Reset (POR) or SLEEP command
0 = After a wake-up on pin change event
Not Applicable
TO: Time-out bit
1 = After power-up, CLRWDT instruction, or SLEEP instruction
0 = A WDT time-out occurred
PD: Power-down bit
1 = After power-up or by the CLRWDT instruction
0 = By execution of the SLEEP instruction
Z: Zero bit
1 = The result of an arithmetic or logic operation is zero
0 = The result of an arithmetic or logic operation is not zero
DC: Digit carry/borrow bit (for ADDWF and SUBWF instructions)
ADDWF
1 = A carry from the 4th low order bit of the result occurred
0 = A carry from the 4th low order bit of the result did not occur
SUBWF
1 = A borrow from the 4th low order bit of the result did not occur
0 = A borrow from the 4th low order bit of the result occurred
C: Carry/borrow bit (for ADDWF, SUBWF and RRF, RLF instructions)
ADDWF
1 = A carry occurred
0 = A carry did not occur
R/W-0
PA1
R/W-0
PA0
R-1
TO
SUBWF
1 = A borrow did not occur
0 = A borrow occurred
R-1
PD
Preliminary
R/W-x
Z
For example, CLRF STATUS will clear the upper three
bits and set the Z bit. This leaves the STATUS register
as 000u u1uu (where u = unchanged).
It is recommended, therefore, that only BCF, BSF and
MOVWF instructions be used to alter the STATUS regis-
ter because these instructions do not affect the Z, DC
or C bits from the STATUS register. For other instruc-
tions, which do affect STATUS bits, see Section 8.0,
Instruction Set Summary.
R/W-x
DC
RRF or RLF
Load bit with LSb or MSb, respectively
R/W-x
C
bit0
PIC16HV540
R = Readable bit
W = Writable bit
- n = Value at POR reset
DS40197B-page 13