ISL81487 Intersil Corporation, ISL81487 Datasheet - Page 8

no-image

ISL81487

Manufacturer Part Number
ISL81487
Description
1/8 Unit Load, 5v, Low Power, High Speed or Slew Rate Limited, Rs-485/rs-422 Transceivers
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL81487EIBZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
ISL81487EIBZ
0
Part Number:
ISL81487EIBZ-T
Manufacturer:
INTERSIL
Quantity:
12 000
Part Number:
ISL81487EIBZ-T
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
ISL81487EIBZ-T
0
Part Number:
ISL81487EIP
Manufacturer:
Intersil
Quantity:
95
Part Number:
ISL81487EIPE
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
ISL81487EIPZ
Manufacturer:
INTERSIL
Quantity:
20 000
Company:
Part Number:
ISL81487IB
Quantity:
406
Part Number:
ISL81487IBZ-T
Manufacturer:
INTERSIL
Quantity:
15 000
Part Number:
ISL81487IBZ-T
Manufacturer:
INTERSIL
Quantity:
20 000
Company:
Part Number:
ISL81487IBZ-T
Quantity:
5 400
Company:
Part Number:
ISL81487LIBZ-T
Quantity:
5 000
Company:
Part Number:
ISL81487LIPZ
Quantity:
1 460
Test Circuits and Waveforms
Application Information
RS-485 and RS-422 are differential (balanced) data
transmission standards for use in long haul or noisy
environments. RS-422 is a subset of RS-485, so RS-485
transceivers are also RS-422 compliant. RS-422 is a point-
to-multipoint (multidrop) standard, which allows only one
driver and up to 10 (assuming one unit load devices)
receivers on each bus. RS-485 is a true multipoint standard,
which allows up to 32 one unit load devices (any
combination of drivers and receivers) on each bus. To allow
for multipoint operation, the RS-485 spec requires that
drivers must handle bus contention without sustaining any
damage.
Another important advantage of RS-485 is the extended
common mode range (CMR), which specifies that the driver
outputs and receiver inputs withstand signals that range
from +12V to -7V. RS-422 and RS-485 are intended for runs
as long as 4000’, so the wide CMR is necessary to handle
ground potential differences, as well as voltages induced in
the cable by external fields.
Receiver Features
These devices utilize a differential input receiver for maximum
noise immunity and common mode rejection. Input sensitivity
is ±200mV, as required by the RS-422 and RS-485
specifications.
Receiver input resistance of 96kΩ surpasses the RS-422
spec of 4kΩ, and is eight times the RS-485 “Unit Load (UL)”
requirement of 12kΩ minimum. Thus, these products are
known as “one-eighth UL” transceivers, and there can be up
to 256 of these devices on a network while still complying
with the RS-485 loading spec.
(SHDN) for ISL8487 and ISL81483 only.
SIGNAL
GENERATOR
t
t
ZH(SHDN)
ZL(SHDN)
PARAMETER
t
t
ZH
ZL
(Note 6)
(Note 6)
t
t
HZ
LZ
(Note 7)
(Note 7)
FIGURE 5A. TEST CIRCUIT
RE
A
B
DE
R
0
0
0
0
0
0
8
RO
+1.5V
+1.5V
+1.5V
-1.5V
-1.5V
-1.5V
FIGURE 5. RECEIVER ENABLE AND DISABLE TIMES
A
15pF
(Continued)
1kΩ
ISL8487, ISL81483, ISL81487
SW
GND
GND
GND
V
V
V
SW
CC
CC
CC
GND
V
CC
Receiver inputs function with common mode voltages as
great as ±7V outside the power supplies (i.e., +12V and
-7V), making them ideal for long networks where induced
voltages are a realistic concern.
All the receivers include a “fail-safe if open” function that
guarantees a high level receiver output if the receiver inputs
are unconnected (floating).
Receivers easily meet the data rates supported by the
corresponding driver, and receiver outputs are three-statable
via the active low RE input.
Driver Features
The RS-485 and RS-422 driver is a differential output device
that delivers at least 1.5V across a 54Ω load (RS-485), and
at least 2V across a 100Ω load (RS-422). The drivers feature
low propagation delay skew to maximize bit width, and to
minimize EMI.
Driver outputs are three-statable via the active high DE
input.
The ISL8487 and ISL81483 driver outputs are slew rate
limited to minimize EMI, and to minimize reflections in
unterminated or improperly terminated networks. Data rate
on these slew rate limited versions is a maximum of
250kbps. ISL81487 drivers are not limited, so faster output
transition times allow data rates of at least 5Mbps.
Data Rate, Cables, and Terminations
RS-485 and RS-422 are intended for network lengths up to
4000’, but the maximum system data rate decreases as the
transmission length increases. Devices operating at 5Mbps
are limited to lengths less than a few hundred feet, while the
250kbps versions can operate at full data rates with lengths
in excess of 1000’.
t
t
ZH
ZL
RE
RO
RO
, t
NOTE 7
, t
NOTE 7
ZH(SHDN)
ZL(SHDN)
NOTE 7
FIGURE 5B. MEASUREMENT POINTS
1.5V
OUTPUT HIGH
1.5V
1.5V
OUTPUT LOW
t
t
HZ
1.5V
LZ
V
V
OH
OL
+ 0.5V
- 0.5V
3V
0V
V
V
V
0V
OH
CC
OL

Related parts for ISL81487