MT9042 Mitel Networks Corporation, MT9042 Datasheet - Page 3

no-image

MT9042

Manufacturer Part Number
MT9042
Description
Global Digital Trunk Synchronizer
Manufacturer
Mitel Networks Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9042AP
Manufacturer:
ZARLINK
Quantity:
1 831
Part Number:
MT9042AP
Manufacturer:
MITEL
Quantity:
20 000
Part Number:
MT9042BP
Manufacturer:
MT
Quantity:
1 000
Part Number:
MT9042BP
Manufacturer:
PHILIPS
Quantity:
1 119
Part Number:
MT9042BP
Manufacturer:
MITEL
Quantity:
20 000
Part Number:
MT9042CP
Manufacturer:
ZARLINK
Quantity:
262
Part Number:
MT9042CP
Manufacturer:
MITEL
Quantity:
20 000
Part Number:
MT9042CP1
Manufacturer:
ZARLINK
Quantity:
2 100
Preliminary Information
Pin Description (continued)
Pin #
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
LOSS2
LOSS1
FSEL2
FSEL1
Name
RSEL
MS2
MS1
RST
C16
GTo
V
V
GTi
C2
C4
C8
SS
DD
Clock 2.048 MHz (CMOS compatible). This output is a 2.048 MHz (E1) output clock
locked to the selected reference input signal.
Clock 4.096 MHz (CMOS compatible). This output is a 4.096 MHz output clock locked to
the selected reference input signal.
Negative Power Supply Voltage. Nominally 0 Volts.
Clock 8.192 MHz (CMOS compatible). This output is an 8.192 MHz output clock locked to
the selected reference input signal.
Clock 16.384 MHz (CMOS compatible). This output is a 16.384 MHz output clock locked
to the selected reference input signal.
Positive Supply Voltage. Nominally +5 volts.
Guard Time Input (TTL Level Schmitt Trigger). This TTL level Schmitt trigger input is
used to determine the threshold level of the RC generated (guard) time constant. This
function filters out unwanted rearrangements between the PRI and SEC reference input
signals.
Guard Time Output (CMOS compatible). This is a CMOS buffered output used to drive the
external RC generated (guard) time constant circuit.
Reference Loss Indicator - 2 Input (TTL compatible). This input, in conjunction with
LOSS1, comprises a set of signals which control the event driven state machine when the
PLL is operating in AUTOMATIC mode (see Table 4).
Reference Loss Indicator - 1 Input (TTL compatible). This input, in conjunction with
LOSS2, comprises a set of signals which control the event driven state machine when the
PLL is operating in AUTOMATIC mode (see Table 4).
Mode Select - 2 Input (TTL compatible). This input, in conjunction with MS1, selects the
PLL mode of operation (i.e.,NORMAL, HOLDOVER, FREERUN, or AUTOMATIC; see Table
1).
Mode Select - 1 Input (TTL compatible). This input, in conjunction with MS2, selects the
PLL mode of operation (i.e., NORMAL, HOLDOVER, FREERUN, or AUTOMATIC; see Table
1).
Input Reference Select (TTL compatible). When LOW this input selects PRI as the
reference input signal, and when HIGH, selects SEC as the reference input signal (see Table
2).
Frequency Select - 2 Input (TTL compatible). This input, in conjunction with FSEL1,
selects the frequency of the input reference source (i.e., 8 kHz, 1.544 MHz, or 2.048 MHz;
see Table 3).
Frequency Select - 1 Input (TTL compatible). This input, in conjunction with FSEL2,
selects the frequency of the input reference source (i.e., 8 kHz, 1.544 MHz, or 2.048 MHz;
see Table 3).
Reset (TTL compatible). This input (active LOW) puts the MT9042 in its reset state. To
guarantee proper operation, the device must be reset after power-up. The time constant for
a power-up reset circuit must be a minimum of five times the rise time of the power supply. In
normal operation, the RST pin must be held low for a minimum of 60 nsec to reset the
device.
Description
MT9042
3-99

Related parts for MT9042