AT90S1200 ATMEL Corporation, AT90S1200 Datasheet - Page 40

no-image

AT90S1200

Manufacturer Part Number
AT90S1200
Description
8-Bit Microcontroller with 1K bytes In-System Programmable Flash
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90S1200
Manufacturer:
TI
Quantity:
146
Part Number:
AT90S1200-12PC
Manufacturer:
ATM
Quantity:
5 530
Part Number:
AT90S1200-12PC
Manufacturer:
ATM
Quantity:
5 120
Part Number:
AT90S1200-12PC
Manufacturer:
ATMEL
Quantity:
1 765
Part Number:
AT90S1200-12PI
Manufacturer:
ATM
Quantity:
3 000
Part Number:
AT90S1200-12PI
Manufacturer:
ATM
Quantity:
3 000
Part Number:
AT90S1200-12PI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT90S1200-12S
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT90S1200-12SC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT90S1200-12YC
Manufacturer:
AT
Quantity:
20 000
Part Number:
AT90S1200-12YI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
40
AT90S1200
4. Give XTAL1 a positive pulse. This loads the command.
B: Load Address High Byte
1. Set XA1, XA0 to “00”. This enables address loading.
2. Set BS to “1”. This selects high byte.
3. Set DATA = Address high byte ($00 - $01).
4. Give XTAL1 a positive pulse. This loads the address high byte.
C: Load Address Low Byte
1. Set XA1, XA0 to “00”. This enables address loading.
2. Set BS to “0”. This selects low byte.
3. Set DATA = Address low byte ($00 - $FF).
4. Give XTAL1 a positive pulse. This loads the address low byte.
D: Load Data Low Byte
1. Set XA1, XA0 to “01”. This enables data loading.
2. Set DATA = Data low byte ($00 - $FF).
3. Give XTAL1 a positive pulse. This loads the data low byte.
E: Write Data Low Byte
1. Set BS to “0”. This selects low data.
2. Give WR a negative pulse. This starts programming of the data byte. RDY/BSY
3. Wait until RDY/BSY goes high to program the next byte.
(See Figure 31 for signal waveforms.)
F: Load Data High Byte
1. Set XA1, XA0 to “01”. This enables data loading.
2. Set DATA = Data high byte ($00 - $FF).
3. Give XTAL1 a positive pulse. This loads the data high byte.
G: Write Data High Byte
1. Set BS to “1”. This selects high data.
2. Give WR a negative pulse. This starts programming of the data byte. RDY/BSY
3. Wait until RDY/BSY goes high to program the next byte.
(See Figure 32 for signal waveforms.)
The loaded command and address are retained in the device during programming. For
efficient programming, the following should be considered:
These considerations also apply to EEPROM programming and Flash, EEPROM and
signature byte reading.
goes low.
goes low.
The command needs only be loaded once when writing or reading multiple memory
locations.
Address high byte needs only be loaded before programming a new 256-word page
in the Flash.
Skip writing the data value $FF; that is, the contents of the entire Flash and
EEPROM after a Chip Erase.
0838H–AVR–03/02