ICP-S ROHM Electronics, ICP-S Datasheet - Page 5

no-image

ICP-S

Manufacturer Part Number
ICP-S
Description
Overcurrent Protection Elements
Manufacturer
ROHM Electronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICP-S0.5
Manufacturer:
RHOM
Quantity:
20 000
Part Number:
ICP-S0.5FTN
Manufacturer:
ROHM
Quantity:
62 651
Part Number:
ICP-S0.5TN
Manufacturer:
ROHM
Quantity:
4 000
Part Number:
ICP-S0.5TN
Manufacturer:
ROHM
Quantity:
65 750
Part Number:
ICP-S0.5TN
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Company:
Part Number:
ICP-S0.5TN
Quantity:
2 000
Part Number:
ICP-S0.7 TN
Manufacturer:
VISHAY
Quantity:
3 200
Part Number:
ICP-S0.7 TN
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
ICP-S0.7FTN
Manufacturer:
ROHM
Quantity:
14 150
Part Number:
ICP-S0.7TN
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Company:
Part Number:
ICP-S0.7TN
Quantity:
1 300
Company:
Part Number:
ICP-S1.0
Quantity:
387
Company:
Part Number:
ICP-S1.0
Quantity:
337
Part Number:
ICP-S1.0TN
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Overcurrent Protection Elements
5. Checks with I
Precautions
I
2
t-t Graph
Breaking current area: The ICP breaks the current in this area.
Deterioration area: Although the ICP does not break the current instantaneously,
the ICP may break the current as a result of ICP deterioration.
Marginal area: The area where the risk of ICP deterioration is low.
Basically avoid using this area.
Safety area: The ICP will not deteriorate or break the current.
Refer to the next section, calculate the I
in the graph. If the value is in the safety area, it is okay to use the selected ICP model.
If the value is, however, beyond the safety area, use an ICP model with higher ratings.
• Note: The inspection and selection of the ICP according to the Joule integral value is
absolutely based on the results of the approximation of the current wave form.
Be sure to inspect all the current wave forms of your application, or otherwise the safety
of the application will not be fully ensured.
• Consider a safety margin with the dispersion of component characteristics taken into
calculation when inspecting and selecting the ICP, if it is impossible to check the worst
current wave form.
• Even though the Joule integral value of the current wave form designed at your end is
within the safety area, it is recommended that you confirm the steady-state current for
the safety of the components
If the steady-state current includes a pulse, surge, or inrush-current, use the I
graph and check that the ICP will not deteriorate regardless of the mode of the
current or the ICP will not break the steady-state current while the ICP is in operation.
2
t-tCharacteristic Graph
Deterioration
Margin area
area
current area
Breaking
I
2
t-t Graph
2
t value, and check the position of the I2t value
Safety area
t (s)
ICP-S Technical Manual
Rev.A
2
t
5/13