MAX5061 Maxim Integrated Products, MAX5061 Datasheet - Page 22

no-image

MAX5061

Manufacturer Part Number
MAX5061
Description
(MAX5060 / MAX5061) Average-Current-Mode DC-DC Controllers
Manufacturer
Maxim Integrated Products
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX5061AUE+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX5061AUE+T
Manufacturer:
MAXIM
Quantity:
2
Part Number:
MAX5061AUEBT
Manufacturer:
MAXIM/美信
Quantity:
20 000
0.6V to 5.5V Output, Parallelable,
Average-Current-Mode DC-DC Controllers
For applications requiring large output current, parallel
two or more MAX5060s (multiphase operation) to
increase the available output current. The paralleled
converters operate at the same switching frequency
but different phases keep the input capacitor ripple
RMS currents to a minimum. The MAX5060 provides
the clock output (CLKOUT), which is 180° out-of-phase
with respect to DH. For the MAX5061, the out-of-phase
clock can be easily generated using a simple inverter
and driving it from the LX node. Use CLKOUT to drive
the second DC-DC converter to double the effective
switching frequency and reduce the input capacitor
ripple current (see Figure 10).
Figure 10. Parallel Configuration of MAX5060
22
V
______________________________________________________________________________________
IN
IN
DIFF
EAN
EAOUT
SENSE-
PGND
MAX5060
SGND CLKOUT
Parallel Operation
RT/SYNC
SENSE+
CSN
CSP
DH
LX
DL
RT/SYNC
IN
DIFF
EAN
EAOUT
PGND
V
IN
MAX5060
SGND
CSN
CSP
DH
LX
DL
To drive multiple converters out-of-phase, use a delay
circuit to set 90° of phase shift (4 paralleled converters),
or 60° of phase shift (6 converters in parallel). Designate
one converter as master and the remaining converters
as slaves. Connect the master and slave controllers in a
daisy-chain configuration as shown in Figure 11.
Choose the appropriate phase shift for minimum ripple
currents at the input and output capacitors. The master
controller senses the output differential voltage through
SENSE+ and SENSE- and generates the DIFF voltage.
Disable the voltage sensing of the slaved controllers by
leaving DIFF unconnected (floating). Figure 11 shows a
typical application circuit using four MAX5060s. This cir-
cuit provides two phases at a 12V input voltage and a
0.6V to 5V output voltage range.
V
IN
V
OUT
LOAD

Related parts for MAX5061