MAX3185 Maxim, MAX3185 Datasheet - Page 6

no-image

MAX3185

Manufacturer Part Number
MAX3185
Description
15kV ESD-Protected / EMC-Compliant / 230kbps RS-232 Serial Port for Motherboards/Desktop PCs
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX31855EASA+T
Manufacturer:
TOSHIBA
Quantity:
20 000
Company:
Part Number:
MAX31855JASA+T
Quantity:
190
Part Number:
MAX31855KASA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX31855KASA
0
Part Number:
MAX31855KASA+T
Manufacturer:
MAXIM
Quantity:
5 000
Part Number:
MAX31855KASA+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX31855KASA+T
0
Part Number:
MAX31855RASA+T
Manufacturer:
MAXIM
Quantity:
2 300
Part Number:
MAX31855SASA+T
Manufacturer:
MAXIM
Quantity:
2 000
Part Number:
MAX31855TASA+T
Manufacturer:
MAXIM
Quantity:
2 500
Part Number:
MAX31855TASA+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX31856MUD+T
Manufacturer:
MAXIM
Quantity:
1 000
Part Number:
MAX3185CAP
Manufacturer:
MAXIM
Quantity:
40
Part Number:
MAX3185CAP
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX3185CAP+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
±15kV ESD-Protected, EMC-Compliant, 230kbps
RS-232 Serial Port for Motherboards/Desktop PCs
Figure 2a shows the Human Body Model, and Figure
2b shows the current waveform it generates when dis-
charged into a low impedance. This model consists of
a 100pF capacitor charged to the ESD voltage of inter-
est, which is then discharged into the device through a
1.5kΩ resistor.
The IEC1000-4-2 standard covers ESD testing and per-
formance of finished equipment; it does not specifically
refer to integrated circuits. The MAX3185 helps you
design equipment that meets Level 4 (the highest level)
of IEC1000-4-2, without additional ESD-protection com-
ponents.
The main difference between tests done using the
Human Body Model and IEC1000-4-2 is higher peak
current in IEC1000-4-2. Because series resistance is
lower in the IEC1000-4-2 ESD test model (Figure 1a),
the ESD withstand voltage measured to this standard is
generally lower than that measured using the Human
Body Model. Figure 1b shows the current waveform for
the ±8kV IEC1000-4-2 Level 4 ESD Contact-Discharge
test.
The Air-Gap test involves approaching the device with a
charge probe. The Contact-Discharge method connects
the probe to the device before the probe is energized.
Figure 2a. Human Body ESD Test Model
6
VOLTAGE
SOURCE
HIGH-
_______________________________________________________________________________________
DC
CHARGE-CURRENT
LIMIT RESISTOR
R
C
100pF
1M
C s
STORAGE
CAPACITOR
R
RESISTANCE
D
DISCHARGE
1500
Human Body Model
IEC1000-4-2
DEVICE
UNDER
TEST
The Machine Model for ESD testing uses a 200pF stor-
age capacitor and zero-discharge resistance. It mimics
the stress caused by handling during manufacturing
and assembly. Of course, all pins (not just RS-232
inputs and outputs) require this protection during man-
ufacturing. Therefore, the Machine Model is less rele-
vant to the I/O ports than are the Human Body Model
and IEC1000-4-2.
Use proper layout to ensure other devices on your
board are not damaged in an ESD strike. Currents as
high as 60A can instantaneously pass into ground, so
be sure to minimize the ground-lead return path to the
power supply. A separate return path to the power sup-
ply is recommend. Trace widths should be greater than
40 mils. Bypass V
tors as close to the part as possible to ensure maxi-
mum ESD protection.
Tie any unused transmitter inputs to GND or V
external protection diodes are needed because the
MAX3185 is not sensitive to power-supply sequencing.
Figure 2b. Human Body Model Current Waveform
__________Applications Information
AMPERES
I
P
36.8%
100%
90%
10%
0
0
t
RL
CC
, V
DD
CURRENT WAVEFORM
TIME
, and V
t
DL
I r
SS
with 0.1µF capaci-
PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)
Machine Model
CC
. No

Related parts for MAX3185