MAX1617 ON Semiconductor, MAX1617 Datasheet - Page 5
MAX1617
Manufacturer Part Number
MAX1617
Description
SMBus Temperature Sensor with Internal and External Diode Input
Manufacturer
ON Semiconductor
Datasheet
1.MAX1617.pdf
(12 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MAX1617AMEE
Manufacturer:
MAXIM
Quantity:
77
Company:
Part Number:
MAX1617AMEE
Manufacturer:
MAXIM
Quantity:
5 510
Company:
Part Number:
MAX1617AMEE
Manufacturer:
MAXIM
Quantity:
72
Part Number:
MAX1617AMEE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX1617AMEE+
Manufacturer:
MAXIM
Quantity:
1 522
Part Number:
MAX1617AMEE+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1617AMEE+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX1617AMEE-T
Manufacturer:
LT
Quantity:
23
Part Number:
MAX1617AMEE-T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1617MEE
Manufacturer:
MAXIM/美信
Quantity:
20 000
SMBus PORT AC TIMING (V DD = 3.3 V, –55 C
f SMB
t LOW
t HIGH
t R
t F
t SU(START)
t H(START)
t SU–DATA
t H–DATA
t SU(STOP)
t IDLE
SCL
SDA
SCL
SDA
A = Start Condition
B = MSB of Address Clocked into Slave
C = LSB of Address Clocked into Slave
D = R/W Bit Clocked into Slave
A = Start Condition
B = MSB of Address Clocked into Slave
C = LSB of Address Clocked into Slave
D = R/W Bit Clocked into Slave
E = Slave Pulls SDA Line Low
Symbol
SMBUS Write Timing Diagram
SMBUS Read Timing Diagram
t SU(START) t H(START)
t SU(START) t H(START)
A
A
SMBus Clock Frequency
Low Clock Period (10% to 10%)
High Clock Period (90% to 90%)
SMBus Rise Time (10% to 90%)
SMBus Fall Time (90% to 10%)
Start Condition Setup Time (90% SCL to 10% SDA)
Start Condition Hold Time
Data in Setup Time
Data in Hold Time
Stop Condition Setup Time
Bus Free Time Prior to New Transition
(for Repeated Start Condition)
I LOW
I LOW I HIGH
B
B
I HIGH
t SU–DATA
t SU–DATA
C
C
Characteristic
F = Acknowledge Bit Clocked into Master
G = MSB of Data Clocked into Slave
H = LSB of Data Clocked into Slave
I = Slave Pulls SDA Line Low
E = Slave Pulls SDA Line Low
F = Acknowledge Bit Clocked into Master
G = MSB of Data Clocked into Master
H = LSB of Data Clocked into Master
(T A = T J )
D
D
http://onsemi.com
MAX1617
125 C; C L = 80 pF, unless otherwise noted.)
E F
E F
5
t H–DATA
G
G
J = Acknowledge Clocked into Master
K = Acknowledge Clock Pulse
L = Stop Condition, Data Executed by Slave
M= New Start Condition
1,000
1,250
Min
4.7
4.7
10
—
—
H
4
4
4
4
H
I = Acknowledge Clock Pulse
J = Stop Condition
K = New Start Condition
I
I J
Typ
—
—
—
—
—
—
—
—
—
—
—
t SU(STOP)
K
t SU(STOP) t IDLE
1,000
Max
100
300
—
—
—
—
—
—
—
—
J
L
t IDLE
K
M
m
m
nsec
nsec
m
m
nsec
nsec
m
m
Unit
kHz
sec
sec
sec
sec
sec
sec