MAX16049 Maxim Integrated Products, MAX16049 Datasheet - Page 39

no-image

MAX16049

Manufacturer Part Number
MAX16049
Description
(MAX16047 / MAX16049) 12-Channel/8-Channel EEPROM-Programmable System Managers
Manufacturer
Maxim Integrated Products
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX16049ACB+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX16049ACB+T
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX16049ETN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
www.DataSheet4U.com
Table 20. EEPROM Fault Log Operation Period
The reset output, RESET, is asserted during power-
up/power-down and deasserts following the reset time-
out period once the power-up sequence is complete.
The power-up sequence is complete when any MON_
inputs assigned to Slot 12 exceed their undervoltage
thresholds. If no MON_ inputs are assigned to Slot 12,
the power-up sequence is complete after the slot
sequence delay is expired.
Table 21. RESET Configuration and Dependencies
System Managers with Nonvolatile Fault Registers
REGISTER r47h[1:0]
FAULT CONTROL
REGISTER/
ADDRESS
EEPROM
19h
00
01
10
11
12-Channel/8-Channel EEPROM-Programmable
______________________________________________________________________________________
BIT RANGE
[1:0]
[6:4]
Failed lines and ADC values saved
Failed lines saved
ADC values saved
No information saved
[2]
[3]
[7]
Reserved
RESET OUTPUT CONFIGURATION
00 = RESET is asserted if at least one of the selected inputs exceeds its undervoltage
threshold
01 = RESET is asserted if at least one of the selected inputs exceeds its early warning
threshold
10 = RESET is asserted if at least one of the selected inputs exceeds its overvoltage threshold
11 = RESET is asserted if any of the selected inputs exceeds undervoltage or overvoltage
thresholds
0 = RESET is an active-low output
1 = RESET is an active-high output
0 = RESET is a open-drain output
1 = RESET is an push-pull output
RESET TIMEOUT
000 = 25µs
001 = 2ms
010 = 25ms
011 = 100ms
100 = 200ms
101 = 400ms
110 = 800ms
111 = 1600ms
DESCRIPTION
RESET
RESET is a configurable output that monitors selected
MON_ voltages during normal operation. Use r19h[1:0]
to configure RESET to assert on an overvoltage fault,
undervoltage fault, or both. Use r19h[3:2] to configure
RESET as an active-high/active-low push-pull/open-
drain output. If desired, configure GPIO4 as a manual
reset input, MR, and pull MR low to assert RESET.
RESET includes a programmable timeout. See Table 21
for RESET dependencies and configuration registers.
DESCRIPTION
MINIMUM REQUIRED SHUTDOWN PERIOD
(ms)
204
168
N/A
60
39