MAX15028 Maxim Integrated Products, MAX15028 Datasheet - Page 6

no-image

MAX15028

Manufacturer Part Number
MAX15028
Description
(MAX15027 / MAX15028) 1A Low-Dropout Regulators
Manufacturer
Maxim Integrated Products
Datasheet
www.datasheet4u.com
1.425V to 3.6V Input, 1A Low-Dropout
Regulators with BIAS Input
6
(Circuit of Figure 1, V
MAX15027
_______________________________________________________________________________________
1, 2, 3
9, 10
4
5
6
7
8
1.80
1.78
1.76
1.74
1.72
1.70
1.68
1.66
1.64
1.62
1.60
-40
PIN
-20
IN
OVERCURRENT THRESHOLD
MAX15028
= 1.8V, V
0
9, 10
vs. TEMPERATURE
1, 2
TEMPERATURE (°C)
3
4
5
6
7
8
20
40
OUT
60
= 1.5V, I
80
V
NAME
BIAS
BIAS
GND
100
OUT
I.C.
EN
SS
FB
EP
IN
= 3.3V
120
OUT
Typical Operating Characteristics (continued)
140
= 1A, T
Regulator Input. 1.425V to 3.6V voltage range. Bypass to GND with at least 1µF
of ceramic capacitance. IN is high impedance when the LDO is shut down.
Internal Circuitry Supply Input. BIAS supplies the power for the internal circuitry.
3V to 5.5V voltage range.
Internally Connected. Connect I.C. directly to GND.
LDO Enable. Drive EN high to enable the LDO or connect to IN (BIAS for
MAX15028) for always-on operation. Drive EN low to disable the LDO and place
the IC in low-power shutdown mode.
Soft-Start Input. For typical operation, connect a 0.1µF capacitor from SS to
GND. The soft-start timing is dependent on the value of this capacitor. See the
Soft-Start section.
Feedback Input. Connect FB to the center of a resistor-divider connected
between OUT and GND to set the output voltage. See the Programming the
Output Voltage section.
Ground
Regulator Output. Bypass OUT to GND with at least 4.7µF of ceramic
capacitance for 1A load operation.
Exposed Paddle. Connect EP to GND and a large copper ground plane to
facilitate package power dissipation.
A
= +25°C, unless otherwise noted.)
80
70
60
50
40
30
20
10
0
0
FUNCTION
CASE TEMPERATURE RISE
0.5
vs. POWER DISSIPATION
POWER DISSIPATION (W)
1.0
1.5
Pin Description
2.0
2.5

Related parts for MAX15028