ELECTRICAL CHARACTERISTICS—MAX6009
(T
1µA SOT23 Precision Shunt
Voltage Reference
Note 1: All devices are 100% production tested at T
Note 2: This parameter is guaranteed by the “reverse breakdown change with current” test.
Note 3: TC is measured by the “box” method; i.e., (V
Note 4: Thermal hysteresis is defined as the change in the +25°C output voltage after cycling the device from T
(C
4
Reverse Breakdown Voltage
Minimum Operating Current
Reverse Breakdown Change
with Current
Reverse Dynamic Impedance
Low-Frequency Noise
Temperature Coefficient
(Note 3)
Long-Term Drift
Thermal Hysteresis (Note 4)
A
L
= -40°C to +85°C, unless otherwise noted. Typical values are at T
= 0.01µF, T
-0.5
-1.0
-1.5
-2.0
-2.5
-3.0
_______________________________________________________________________________________
0.5
0
-50
I
V
R
OUT
PARAMETER
= 1.2µA
= 2.5V
TEMPERATURE DRIFT
A
= +25°C, unless otherwise noted.)
TEMPERATURE (°C)
0
50
SYMBOL
100
I
RMIN
V
TC
R
T
I
V
I
I
I
I
I
1000h at T
R
R
R
R
R
R
A
2.5
2.0
1.5
1.0
0.5
R
= 1.2µA, f = 0.1Hz to 10Hz
= 1.2µA
0
= 1.2µA
= 1.2µA to 200µA
= 200µA to 2mA
= 1.2µA to 2mA (Note 2)
= +25°C,
change <0.2% from V
A
0.001
MAX
= +25°C and are guaranteed by design for T
T
A
- V
= +85°C T
A
MIN
0.01
= +25°C
REVERSE CURRENT (mA)
V
OUT
) / (T
CONDITIONS
A
MAX6006
vs. CURRENT
= -40°C
MAX
A
0.1
MAX6009A (0.2%)
MAX6009B (0.5%)
MAX6009A
MAX6009B
= +25°C.) (Note 1)
Typical Operating Characteristics
- T
R
at I
MIN
T
1
A
= +25°C
R
).
= 1.2µA
10
1.5V
2.9940
2.9850
0
MIN
A
= T
MIN
3.000
3.000
TYP
150
200
0.5
75
to T
MAX6006
STARTUP
MIN
MAX
20ms/div
3.0060
3.0150
to T
, as specified.
MAX
1.0
1.7
2.7
2.2
30
75
1.2µA
MAX
.
ppm/°C
UNITS
µV
ppm
ppm
mV
µA
V
p-p