MAX11803 Maxim Integrated Products, MAX11803 Datasheet - Page 46

no-image

MAX11803

Manufacturer Part Number
MAX11803
Description
(MAX11800 - MAX11803) Ultra-Small Resistive Touch-Screen Controllers
Manufacturer
Maxim Integrated Products
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX11803EWC+T
Manufacturer:
Maxim
Quantity:
7 472
www.DataSheet4U.com
Low-Power, Ultra-Small Resistive Touch-Screen
Controllers with I
TSC conversion commands are only to be used in
direct conversion mode (AUTO = 0). Conversion com-
mands issued during autonomous mode are ignored.
All panel setup and measurement operations are auto-
mated when in autonomous mode (AUTO = 1).
Commands must be issued in write mode to be execut-
ed. There are two types of commands: panel setup reg-
isters (0x6x) and measurement/conversion registers
(0x7x). All measurement commands indicate that the
ADC is used and the ADC can begin to power up once
the 0x7x header has been recognized. All measure-
ment commands modify the target data register upon
the conclusion of the measurement command. The
Table 22. Measurement Commands
46
HEX
7xh
7xh
7xh
7xh
7xh
7xh
7xh
7xh
______________________________________________________________________________________
R6
1
1
1
1
1
1
1
1
R5
1
1
1
1
1
1
1
1
R4
1
1
1
1
1
1
1
1
Measurement Commands
R3
0
0
0
0
1
1
1
1
R2
0
0
1
1
0
0
1
1
R1
0
1
0
1
0
1
0
1
Panel Setup and
CONT
CONT
CONT
CONT
R0
(0)
(0)
(0)
(0)
2
C/SPI Interface
ACCESS
Write
Write
Write
Write
Write
Write
Write
Write
PAIRABLE
No
No
No
No
No
No
No
No
CONT bit impacts the setup of the panel and ADC fol-
lowing the command. For panel setup commands and
combined commands, the user setting of this bit (R0) is
ignored. For these commands, the internal assumption
is shown in parentheses in Table 22.
The CONT bit impacts the setup of the panel and/or ADC
following the command (see command descriptions for
details). For some commands, the user setting of this bit
(R0) is ignored; for these commands the internal
assumption is shown in parentheses in Tables 8 and 22.
By definition, panel setup and measurement com-
mands are NOT pairable in write mode as each com-
mand modifies the panel setting both during the
command and after it (based on conversion executions
and CONT bit settings).
COMMAND
LENGTH
8
8
8
8
8
8
8
8
X, Y = combined measurement
X, Y, Z1 = combined measurement
X, Y, Z1, Z2 = combined measurement
AUX = measurement
X = measurement
Y = measurement
Z1 = measurement
Z2 = measurement
OPERATION