FLEX405 ETC, FLEX405 Datasheet - Page 2

no-image

FLEX405

Manufacturer Part Number
FLEX405
Description
Fire Alarm Control Panel with Built-in DACT and Remote-site Upload/download Capability
Manufacturer
ETC
Datasheet
Ordering Information
Page 2 of 4
F405
XRM-24
SAN-405
ADM-24
RM-5F
CAC-5F
PRT-24
PK-CD
MCBL-7
BB-17F
TR-3-R
52223
Five-zone, 24-volt fire alarm control communicator.
Includes backbox, transformer, technical manual, and
frame-and-post operating instruction sheet.
120 VAC, 100 VA transformer expands NAC power from
3.0 to 5.0 amps.
Five-zone remote annunciator (RZA-5F), mounts to a
single-gang box (requires ADM-24) .
Annunciator driver module (supports SAN-405).
Five-zone relay module, provides contact-by-zone.
Class A converter module. Converts all Class B initiating
device circuits (zones) to Class A.
Printer interface module, provides an EIA-232 printer
output. Includes cable, DB9F and DB25 adapter.
Contains programming software for Windows®-based PC
computer (cable not included) .
DACT phone cord, 7 feet (2.134 m) long (two required) .
Battery backbox, required for batteries over 7 AH.
Trim ring.
Flex 405 Installation and Maintenance Manual.
Flex 405 CS-2405 02/15/05
Specifications
• Single PC board design using Surface
• Two modular telephone jacks for connec-
AC power
• 120 VAC, 50/60 Hz, 2.3 A.
• Wire size: minimum 14 AWG (2.0 mm²) with
• Built-in brownout circuitry, built-in voltmeter.
Communicator
• One line-active indicator for each of two
• “Kiss-Off” signal LED.
• Dual “low telephone voltage detect” circuitry.
• Programmable event codes per each format.
• Up to 62 transmitted events/messages.
• Five zones may be configured to five
Communication formats
Express formats allow complete transaction to
be communicated in under five seconds.
• 20 PPS, 3+1 standard and expanded.
• 20 PPS, 4+1 standard and expanded.
• 20 PPS, 4+2 standard and expanded.
• 4+1 and 4+2 Ademco Express.
Initiating device circuits (zones)
• The Flex 405 includes five programmable
• Each zone may support two-wire smoke
• All circuits are power-limited and fully
• All circuits allow up to 100 ohms of line
Notification appliance circuits
• Two Style Z/Y (Class A/B) @ 2.5 A each.
• All circuits are fully power-limited and meet
Auxiliary outputs
• Resettable four-wire smoke detector power @
• Integral Form-C Alarm and Trouble relays.
• Relay drivers for supervisory and communi-
Cabinet specifications
• The compact cabinet can be surface- or
• Knockouts on the top, sides, and back
• Dimensions, Door: 15.219” high x 14.219”
Mount Technology (SMT).
tion to RJ31X/modules.
600-volt insulation.
phone lines.
Selectable/deselectable transmissions of 62
events.
channels as a slave communicator (channels
are auto-resettable.
initiating device circuits (zones). Circuits 1, 2,
4, and 5 are Style B (Class B). Circuit 3 is
Style D (Class A). Use the Class A converter
module (P/N CAC-5F) to convert all Class B
IDCs to Class A.
detectors. Programming options include:
waterflow (silenceable/non-silenceable),
supervisory (standard/auto-reset), pull
station, normally-open-contact device.
supervised.
resistance. Use 12 to 18 AWG wire (3.1 to
0.78 mm²).
UL power-limiting requirements.
300 mA. Non-resettable power @ 300 mA.
cation fail.
semi-flush-mounted.
provide ease of wire entry.
wide (38.655 cm H x 36.115 cm W).
Backbox: 15.0” high x 14.5” wide x 3.0”
deep (38.1 cm H x 36.83 cm W x 7.62 cm D).
Trim ring (P/N TR-1-R): 18.125” high x
17.62” wide (46.038 cm H x 44.755 cm W).

Related parts for FLEX405