ACS102 ST Microelectronics, Inc., ACS102 Datasheet - Page 3

no-image

ACS102

Manufacturer Part Number
ACS102
Description
ac Line Switch
Manufacturer
ST Microelectronics, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS102
Manufacturer:
ST
0
Part Number:
ACS102
Manufacturer:
ST
Quantity:
20 000
Part Number:
ACS102-5T
Manufacturer:
ST
0
Part Number:
ACS102-5T1
Manufacturer:
STMicroelectronics
Quantity:
2 850
Part Number:
ACS102-5T1
Manufacturer:
ST
0
Part Number:
ACS102-5T1-TR
Manufacturer:
ST
0
Part Number:
ACS102-5T1-TR
Manufacturer:
ST
Quantity:
20 000
Part Number:
ACS102-5TA
Manufacturer:
STMicroelectronics
Quantity:
360
Part Number:
ACS102-5TA
Manufacturer:
ST
0
Part Number:
ACS102-6T1-TR
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
ACS102-6T1-TR
Quantity:
7 500
Part Number:
ACS102-6TA-T-R
Quantity:
6 000
Table 1: Low power load turn off commutation requirement (230V AC applications).
AC LINE SWITCH BASIC APPLICATION
The ACS102 device is well adapted to washing machines, dish washers, tumble driers, refrigerators, water
heaters, and cookware. It has been designed especially to switch on & off low power loads such as sole-
noids, valves, relays, dispensers, micro-motors, pumps, fans, door locks, and low power lamps bulbs.
Pin COM : Common drive reference, to connect to the power line neutral
Pin G
Pin OUT
This ACS™ switch is triggered with a negative gate current flowing out of the gate pin G. It can be driven di-
rectly by the digital controller through a resistor as shown on the typical application diagram. No protection
device are required between the gate and COM terminals.
The SO-8 version allows to connect several ACS102 devices on the same cooling PCB pad which is the
COM pin.
In appliance systems, the ACS102 switch intends to drive low power loads in full cycle ON / OFF mode.
The turn off commutation characteristics of these loads are described in Table 1.
Thanks to its thermal and turn-off commutation characteristics, the ACS102 switch drives a load, such as
door lock, lamp, relay, valve and micro motor, up to 0.2A without any turn-off aid circuit. Switching off the
ACS within one full AC line cycle will extend its current up to 0.3 A.
TYPICAL APPLICATION DIAGRAM
Door lock, lamp
Relay Valve
Dispenser
Micro-motor
Pump Fan
LOAD
: Switch Gate input to connect to the digital controller through a resistor
: Switch Output, to connect to the load
Load IRMS
current
< 0.2
< 0.2
< 0.3
(A)
L
N
MAINS
AC
- Vcc
FACTOR
POWER
D
> 0.7
> 0.2
1
COM
S
ON
OUT
LOAD
L
R
G
ACS102
ST 72 MCU
(dI/dt)c
(A/ms)
< 0.15
< 0.1
< 0.1
(dV/dt)c
< 0.15
(V/ s)
< 10
< 5
ACS102-5Tx
TURN-OFF
DELAY
(ms)
< 10
< 10
< 20
3/8