STP-2000-2115 Signal Transformer Inc., STP-2000-2115 Datasheet - Page 17

no-image

STP-2000-2115

Manufacturer Part Number
STP-2000-2115
Description
Power Transformers & High Frequency Magnetics Your One Source For All Your Magnetics Needs!
Manufacturer
Signal Transformer Inc.
Datasheet
Class 2 Transformers designed for
Chassis Mounting
Custom versions available upon request.
Inherently or Non-Inherently Limited
www.signaltransformer.com
* Non-inherently limited
Maximum secondary fuse value specified
All primaries are 115/230 V, 50/60 Hz
Part Number
CL2-25-12
CL2-25-24
CL2-40-12
CL2-40-24
CL2-80-24
Primaries are designed to be used simultaneously.
That is, they must be used either series or parallel
connected (as one winding).
50/60 Hz
50/60 Hz
115V
115V
SecondaryRMS Rating
5
2
6
1
12V @ 2.10A
24V @ 1.05A
12V @ 3.33A
24V @ 1.66A
24V @ 3.33A
Signal’s CL2 transformers are available in printed circuit and chassis mount
versions. They are supplied as inherently or non-inherently limited units that are
UL 1585 / UL 5085 recognized.
General Specifications
• Power - 25 VA to 80 VA
• Dielectric Strength - 4000 Vrms Hipot
• Primaries - Dual primaries, 115/230 V, 50/60 Hz,
• Secondaries - Single secondary
• Class 2 Rating - Inherently or non-inherently limited (secondary fuse
• Electrostatic Shield - Not necessary, split or dual bobbin construction
• Terminals - Solder lug/quick connect type terminals
• Insulation System - Class F insulation, 155º C
• Flammability Rating - Bobbin and shroud material meet UL 94V0
Agency Certifications
• UL recognized to UL 1585 / UL 5085-3, File # E116583
• CSA certified to C22.2 #66.1
Indicates like polarity
requirements below)
14
Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208
sales@signaltransformer.com • techhelp@signaltransformer.com
©2008 Signal Transformer — Specification subject to change without notice. 07.08
Secondary Fuse Required
12
7
2.5A*
1.5A*
4.0A*
2.0A*
3.5A*
500 Bayview Avenue, Inwood, NY 11096

Related parts for STP-2000-2115