MDI40A0BA2XXIX Carlo Gavazzi, MDI40A0BA2XXIX Datasheet - Page 3

no-image

MDI40A0BA2XXIX

Manufacturer Part Number
MDI40A0BA2XXIX
Description
(MDI40A Series) Panel Meters and Controllers
Manufacturer
Carlo Gavazzi
Datasheet
MDI 40 A
Software Functions
Peak and valley values
Password
Measurement selection
Scaling factor
Supply Specifications
AC voltage
DC supply
Power consumption
Specifications are subject to change without notice (28.10.99)
Insulation
Insulation
Operating mode
1st level
2nd level
3rd level
Automatic storage (RAM
only) of the min. and max.
value measured from the
last reset
Numeric code of max. 3 di-
gits; 3 protection levels of
the programming data
Password “0”, no protection
Password from 1 to 127, all
data are protected
Password for 128 to 255, all
data protected except for
the alarm setpoints
AC/DC current
Electrical scale compression,
compression/expansion of the
displayed scale (max. 2 with-
out filter, > 2 with filter).
230 VAC -15%+10%
50/60 Hz, (standard)
24 VAC, 48 VAC, 115 VAC,
120 VAC, 240 VAC,
-15%+10%
50/60 Hz (on request)
4000 V
all the other inputs/outputs
9 to 32 VDC, galvanic
insulation,
max. inrush current:
≤ 1.2 A/200 ms (on request)
40 to 150 VDC, galvanic
insulation,
max. inrush current:
≤ 0.6 A/200 ms (on request)
500 V
other inputs/outputs
5 VA (basic instrument),
7 VA max. with signal output
rms
rms
supply input to all
supply input to
General Specifications
Operating temperature
Storage temperature
Insulation reference voltage
Dielectric strength
Noise rejection
EMC
Safety standards
Connector
Housing
Degree of protection
Weight
Approvals
Scaling factor (cont.)
Diagnostics
Filter
NMRR
CMRR
Dimensions
Material
Electrical scale
Decimal point position
Displayed scale
Filter operating range
Filtering coefficient
Over range
Under range
0° to +50°C, 32° to 122°F
(R.H. < 90% non-condensing)
-10° to +60°C, 14° to 140°F
(R.H. < 90% non-condensing)
300 V
4000 V
40 dB, 40 to 60 Hz.
100 dB, 40 to 60 Hz
IEC 60801-2, IEC 60801-3,
IEC 60801-4 (level 3),
EN 50081-1, EN 50082-1
EN 61 010-1, IEC 61010-1,
VDE 0411
Screw-type, detachable
1/8 DIN, 48 x 96 x 124 mm
ABS,
self-extinguishing: UL 94 V-0
IP 65 (standard)
Approx 520 g (signal output
and packing included)
UL,CSA, CE
Programmable within the
whole measuring range
Programmable within the
displaying range
Programmable within the
whole displaying range
The display flashes when the
limits of the displayed range
are exceeded, the data are
updated up to the maximum
read-out
EEE indication (AC/DC)
-EE indication (DC)
From 0 to 3999
From 1 to 255
rms
rms
to ground
for 1 minute
3