DIESEL ENGINE-GENERATOR SET
2000-XC6DT2
2000 ekW
1860 ekW
480 - 13.8kV
SySTEm RATINGS
Standby
Prime
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration.
** UL2200 Offered
/
/
60 Hz
60 Hz
480V**
3
0.8
60
2000
2500
3007
5800
744RSL4054
130°C/27°C
4 BAR WYE
480V
3
0.8
60
1860
2325
2797
5800
744RSL4054
105°C/40°C
4 BAR WYE
/
/
Prime
Standby
600V
3
0.8
60
2000
2500
2406
3600
744RSS4292
125°C/40°C
4 BAR WYE
600V
3
0.8
60
1860
2325
2237
3600
744RSS4292
105°C/40°C
4 BAR WYE
4160V
3
0.8
60
2000
2500
347
5100
744FSM4374
130°C/27°C
4 BAR WYE
4160V
3
0.8
60
1860
2325
323
5100
744FSM4374
105°C/40°C
4 BAR WYE
12470V
3
0.8
60
2000
2500
116
C/F
1020FDH5582
130°C/27°C
4 BAR WYE
12470V
3
0.8
60
1860
2325
108
C/F
1020FDH5582
105°C/40°C
4 BAR WYE
A tognum grouP BrAnd
13200V
3
0.8
60
2000
2500
109
C/F
1020FDH5582
130°C/27°C
4 BAR WYE
13200V
3
0.8
60
1860
2325
102
C/F
1020FDH5582
105°C/40°C
4 BAR WYE
13800V
3
0.8
60
2000
2500
105
C/F
1020FDH5582
130°C/27°C
4 BAR WYE
13800V
3
0.8
60
1860
2325
97
C/F
1020FDH5582
105°C/40°C
4 BAR WYE

Related parts for 2000-XC6DT2

2000-XC6DT2 Summary of contents

Page 1

... DIESEL ENGINE-GENERATOR SET 2000-XC6DT2 2000 ekW / Standby / / 1860 ekW 60 Hz Prime 480 - 13.8kV SySTEm RATINGS Standby Voltage (L-L) 480V** Phase 2000 kVA 2500 AMPS 3007 skVA@30% Voltage Dip 5800 Generator Model* 744RSL4054 Temp Rise 130°C/27°C Connection 4 BAR WYE ...

Page 2

... Sustained short circuit current 300% of the rated current for up www.DataSheet4U.com to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation 2 2000-XC6dt2 / / / / // Complete Range of Accessories Permanent Magnet Generator (PMG Brushless, Rotating Field - 300% Short Circuit Capability ...

Page 3

... Fuel System // Fuel Supply Connection Size Fuel Return Connection Size Maximum Fuel Lift: ft (m) Recommended Fuel Total Fuel Flow: gal/hr (lit/hr) www.DataSheet4U.com 3 2000-XC6dt2 / / / / Fuel Consumption // MTU Detroit Diesel 16V4000 G43 At 100% of Power Rating: gal/hr (lit/hr) (T1638A36) At 75% of Power Rating: gal/hr( lit/hr) ...

Page 4

... Fax +49 7541 90 7084 / powergenregion1@mtu-online.com Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com 4 2000-XC6dt2 / / / / Weight (less tank) 36,326 lb (16,477 kg) Standby Full Load ...

Related keywords