3.
POWER DOWN FUNCTION
In order to reduce the power consumption, in case of cascade connection, S6B2104 has a "power down
function".
.
- EOB and EIB pins works as input terminals.
- EOB and EIB pins work as output terminals. These terminals are set to the "H" level immediately after ENABLE F/F is
- The operation of ENABLE F/F is terminated and held unchanged until the next load pulse is detected. (For cascade
ENABLE F/F stops display data at "H" level input. ENABLE F/F starts display data at "L" level input.
initialized by the load pulse. Upon completion of 80-bit serial/parallel conversion using the shift clock input from the
CL2 terminal, these terminals are then set to the "L" level.
connection, refer to the application circuit drawing)
EOB
EIB
2nd EOB (output)
1st EOB (output)
2nd EIB (input)
1st EIB (input)
Shift CL2
Shift CL2
Enable output
CL1
CL2
Enable input
SHL = H (EIB = Input, EOB = Output)
First S6B2104’ s EOB should be connected to second S6B2104’ s EIB.
1
EOB of Nth driver is connected to EIB of (N+1)th driver S6B2104
2
19
Disable
Enable
20
1
1
2
2
19
19
20
20
20
H
L
S6B2104