B58610T4600A001 EPCOS AG, B58610T4600A001 Datasheet - Page 5

no-image

B58610T4600A001

Manufacturer Part Number
B58610T4600A001
Description
Pressure Sensors
Manufacturer
EPCOS AG
Datasheet
Preliminary data
Symbols and terms
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
AS SEN PD
Please read Cautions and warnings and
Important notes at the end of this document.
Pressure sensors
Absolute pressure transducers
Storage temperature range T
A storage of the pressure sensor within the temperature range T
and without applied pressure and supply voltage will not affect the performance of the pressure sensor.
Operating temperature range T
An operation of the pressure sensor within the temperature range T
will not affect the performance of the pressure sensor.
Rated pressure p
Within the rated pressure range 0 up to p
Overpressure p
Pressure cycles within the pressure range 0 up to p
Supply voltage V
V
The output voltage V
DC break down voltage V
The pressure sensor withstands a high voltage between the stainless steel pressure connection and the electrical
connection V
Offset V
The offset V
Sensitivity S
Within the pressure range 0 up to p
Nonlinearity L (including pressure hysteresis)
The nonlinearity is the deviation of the real sensor characteristic V
It can be approximated by a polynomial of second order, with the maximum at p
The equation to calculate the nonlinearity is:
Temperature hysteresis
The temperature hysteresis is the change of offset, starting from the value at 25 ° C after a temperature change
and return to 25 ° C. Determined during temperature cycles in operating temperature range (cycles with 1 K/min).
(Full Scale): FS = V
Temperature coefficients of the bridge resistance
Bridge resistance at temperature T
Values are valid within the operating temperature range T
Out of the operating temperature range, the deviation may increase.
Temperature coefficients of the sensitivity
Sensitivity at temperature T
Values are valid within the operating temperature range T
Out of the operating temperature range, the deviation may increase.
Temperature coefficient of offset TCV
Offset at temperature T
Values are valid within the operating temperature range T
Out of the operating temperature range, the deviation may increase.
DD,max
is the maximum permissible supply voltage, which can be applied without damages.
0
0
DD
is the signal output V
and V
OV
DD
r
FS
out
out
= S · p
x
is ratiometric (V
: V
(all short circuited) without damage.
0
is
x
(T
: S(T
r
x
) = V
st
a
x
) = S(25 ° C) · [ 1 +
out
x
r
: R
0
(25 ° C) + TCV
the output voltage is V
(p = 0) at zero pressure.
S
out
(T
0
r
x
~ V
the signal output characteristic corresponds to this specification.
) = R
L
DD
S
S
).
(25 ° C) · [ 1 +
,
V
V
0
S
ov
out
out
· (T
Page 5 of 7
will not affect the performance of the pressure sensor.
S
p (
p (
RS
x
· (T
– 25 ° C) · V
,
x
r
a,min
a,min
a,min
)
out
)
x
RS
– 25 ° C) +
(p
up to T
up to T
up to T
V
V
x
) = V
RS
st,min
0
0
out
· (T
a,min
0
DD
= f(p) from the ideal straight line.
up to T
a,max
a,max
a,max
p
p
+ S · p
x
x
r
– 25 ° C) +
up to T
S
· (T
st,max
x
x
a,max
– 25 ° C)
x
= p
RS
r
/ 2 .
· (T
2
]
x
– 25 ° C)
2
]
AT2 series
2009-08-03

Related parts for B58610T4600A001