COMMON SPECIFICATIONS
Temperature and humidity
Temperature range
Humidity range
Vibration and shock
Vibration
Shock
Withstand voltage and insulation resistance
Withstand voltage
Insulation resistance
BLOCK DIAGRAM
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
• All specifications are subject to change without notice.
AC input
100
80
70
60
40
20
L
N
–10
0
Input
filter
circuit
Ambient temperature(˚C)
Available operating range
(outside of warranty)
Operating(°C)
Storage(°C)
Operating(%)RH
Storage(%)RH
5 to 10Hz
10 to 55Hz
Acceleration
Pulse duration
Input terminal to ground terminal(G)
Input terminal to output terminal
Input terminal to ground terminal(G)
Input terminal to output terminal
Output terminal to ground terminal(G)
10
Input
rectifier
circuit
20
30
Surge
current
limiting
circuit
40
Input
smoothing
circuit
50
60
Over-
current
detection
circuit
Control circuit
0 to +60[Derating is necessary when operating environment temperature exceed 50°C.]
–25 to +75
20 to 95[Maximum wet-bulb temperature: 35°C, without dewing]
All amplitude 10mm[3 directions, each 1h]
Acceleration 19.6m/s
196m/s
11±5ms
Eac: 2kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Edc: 500V, 100M
Power
switching
circuit
Drive
circuit
2
(20G)[3 directions, each 3 times]
min. [Normal temperature, normal humidity]
2
(2G)[3 directions, each 1h]
Output rectifying
and
smoothing circuit
Output rectifying
and
smoothing circuit
Control
circuit
Series
regulator
002-01 / 20051206 / ea152_fcp.fm
DC output
V
V
0V