G5SB-14 Omron Corporation, G5SB-14 Datasheet - Page 2

no-image

G5SB-14

Manufacturer Part Number
G5SB-14
Description
Pcb Relay G5sb
Manufacturer
Omron Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5SB-14 12VDC
Manufacturer:
OMRON
Quantity:
5 400
Part Number:
G5SB-14 DC12
Manufacturer:
OMRON
Quantity:
6 821
Part Number:
G5SB-14 DC24
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
G5SB-14-12DC
Manufacturer:
SANYO
Quantity:
7 760
Part Number:
G5SB-14-12VDC
Manufacturer:
AXICOM
Quantity:
12 000
Part Number:
G5SB-14-12VDC
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Company:
Part Number:
G5SB-14-12VDC
Quantity:
5 655
Part Number:
G5SB-14-24VDC
Quantity:
5 400
Company:
Part Number:
G5SB-14-24VDC
Quantity:
5 655
Company:
Part Number:
G5SB-14-DC12V
Quantity:
5 655
Company:
Part Number:
G5SB-14-DC24V
Quantity:
5 655
■ Contact Ratings
Note: P level: λ
■ Characteristics
Note: 1. The data shown above are initial values.
124
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Insulation resistance (See note 4.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy (See note 5.)
Ambient temperature
Ambient humidity
Weight
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The operating time is possible with the operating voltage imposed with no contact bounce at an ambient temperature of 23°C.
4. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5. The electrical life data items shown are possible at 23°C.
PCB Relay
60
=0.1 x 10
–6
operation (with an operating frequency of 120 operations/min.)
G5SB
Resistive load
3 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO) at 250 VAC
3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC
Ag alloy
5 A (NO)/3 A (NC)
250 VAC, 30 VDC
5 A (NO)/3 A (NC)
1,250 VA, 150 W (NO)
750 VA, 30 W (NC)
10 mA at 5 VDC
100 mΩ max. initial
10 ms max.
5 ms max.
1,000 MΩ min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 x 50 μs)
Destruction:10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:1,000 m/s
Malfunction:Energized: 100 m/s
Non-energized: 100 m/s
Mechanical:
Electrical:
Switching frequency: 1,800 operations per hour
Operating: –40°C to 70°C with no icing or condensation
Operating: 5% to 95%
Approx. 6.5 g
5,000,000 operations (18,000 operations per hour)
200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations: 5 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations: 5 A (NO) at 250 VAC resistive load
10,000 operations: 3 A (NC) at 250 VAC resistive load
10,000 operations: 5 A (NO)/3 A (NC) at 30 VDC resistive load
2
(approx. 100G)
2
(approximately 10G)
2
(approximately 10G)

Related parts for G5SB-14