ADL5500 Analog Devices, Inc., ADL5500 Datasheet - Page 18

no-image

ADL5500

Manufacturer Part Number
ADL5500
Description
100 Mhz To 6 Ghz Trupwr Detector
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADL5500
Manufacturer:
WLCSP-4
Quantity:
6 540
Part Number:
ADL5500ACBZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADL5500ACBZ
Quantity:
1 900
Part Number:
ADL5500ACBZ-P2
Manufacturer:
A/D
Quantity:
213
Part Number:
ADL5500ACBZ-P2
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADL5500ACBZ-P2
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADL5500ACBZ-P7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADL5500ACBZ-P7
Quantity:
2 545
Company:
Part Number:
ADL5500ACBZ-P7
Quantity:
2 545
ADL5500
DEVICE CALIBRATION AND ERROR CALCULATION
Because slope and intercept vary from device to device, board-
level calibration must be performed to achieve high accuracy. In
general, calibration is performed by applying two input power
levels to the ADL5500 and measuring the corresponding output
voltages. The calibration points are generally chosen to be
within the linear operating range of the device. The best fit line
is characterized by calculating the slope and intercept using the
following equations:
where:
V
V
Once slope and intercept have been calculated, an equation can
be written that allows calculation of an (unknown) input power
based on the measured output voltage.
For an ideal (known) input power, the law conformance error of
the measured data can be calculated as
Figure 42 includes a plot of the error at 25°C, the temperature at
which the ADL5500 is calibrated. Note that the error is not zero.
This is because the ADL5500 does not perfectly follow the ideal
linear equation, even within its operating region. The error at
the calibration points is, however, equal to zero by definition.
IN
RMS
Figure 42. Error from Linear Reference vs. Input at −40°C, +25°C, and +85°C
is the rms input voltage to RFIN.
–1
–2
–3
Slope = (V
Intercept = V
V
ERROR (dB) =
20 × log [(V
is the voltage output at VRMS.
3
2
1
0
–25
IN
vs. +25°C Linear Reference, Frequency 900 MHz, Supply 5.0 V
= (V
–20
RMS
RMS2
− Intercept)/Slope
RMS, MEASURED
RMS1
− V
–15
− (Slope × V
RMS1
–10
)/(V
− Intercept)/(Slope × V
INPUT (dBm)
IN2
–40°C
+85°C
–5
− V
IN1
)
IN1
)
+25°C
0
5
IN, IDEAL
10
)] (4)
15
Rev. A | Page 18 of 24
(1)
(2)
(3)
Figure 42 also includes error plots for the output voltage at
−40°C and +85°C. These error plots are calculated using the
slope and intercept at +25°C. This is consistent with calibration
in a mass-production environment where calibration at
temperature is not practical.
CALIBRATION FOR IMPROVED ACCURACY
Another way of presenting the error function of the ADL5500 is
shown in Figure 43. In this case, the dB error at hot and cold
temperatures is calculated with respect to the transfer function
at ambient. This is a key difference in comparison to the
previous plots. Up to now, the errors have been calculated with
respect to the ideal linear transfer function at ambient. When
this alternative technique is used, the error at ambient becomes
equal to 0 by definition (see Figure 43).
This plot is a useful tool for estimating temperature drift at a
particular power level with respect to the (nonideal) response at
ambient. The linearity and dynamic range tend to be improved
artificially with this type of plot because the ADL5500 does not
perfectly follow the ideal linear equation (especially outside of
its linear operating range). Achieving this level of accuracy in
an end application requires calibration at multiple points in the
device’s operating range.
In some applications, very high accuracy is required at just one
power level or over a reduced input range. For example, in a
wireless transmitter, the accuracy of the high power amplifier
(HPA) is most critical at or close to full power. The ADL5500
offers a tight error distribution in the high input power range,
as shown in Figure 43. The high accuracy range, centered
around +3 dBm at 900 MHz, offers 8.5 dB of ±0.1 dB detection
error over temperature. Multiple point calibration at ambient
temperature in the reduced range offers precise power
measurement with near 0 dB error from −40°C to +85°C.
Figure 43. Error from +25°C Output Voltage at −40°C, +25°C, and +85°C
–1
–2
–3
3
2
1
0
After Ambient Normalization, Frequency 900 MHz, Supply 5.0 V
–25
–20
–15
–10
INPUT (dBm)
–40°C
+85°C
–5
+25°C
0
5
10
15

Related parts for ADL5500