G3J-S Omron Corporation, G3J-S Datasheet - Page 2

no-image

G3J-S

Manufacturer Part Number
G3J-S
Description
Soft-start Solid State Contactors
Manufacturer
Omron Corporation
Datasheet
Ordering Information
■ List of Models
Note: When ordering, specify the rated supply voltage.
■ Accessories (Order Separately)
Mounting Bracket
Note: Use this Bracket when mounting Thermal Relay to a G3J-series SSR.
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Power Supply
Operation Circuit
Note: Refer to Safety Precautions for the G3J-T, G3J-S, and G3J.
Main Circuit
Note: No single-phase load can be connected.
3
Rated supply voltage
Operating voltage range
Current consumption
Input current
Input method
No-voltage input (short-circuiting and
opening inputs) (See note.)
Rated load voltage
Load voltage range
Rated carry current
Min. load current
Peak-value current resistivity
Overload resistance
Closed current
(effective value)
Breaking current
(effective value)
Applicable load
R99-14 FOR G3J (See note.)
Number of
elements
Model
Item
Insulation method
Phototriac
AC3
AC4
AC3
AC4
3-phase inductive
motor (AC3 AC4
AC53-a)
Resistive load
(AC1) (See note.)
12 to 24 VDC
12 to 24 VDC
10.2 to 26.4 VDC
100 mA max. (at 12 to 24 VDC)
10 mA max. (at 12 to 24 VDC)
Short-circuiting or opening terminals 1 and COM or 2 (+) and 1
SSR input turned ON: A maximum residual voltage of 2 V between short-circuited terminals
SSR input turned OFF: A maximum leakage current of 0.15 mA
Relay input: For minute signals
200 to 400 VAC (50/60 Hz)
180 to 440 VAC (50/60 Hz)
5.5 A (Ta = 40°C)
0.5 A
220 A, 60 Hz, 1 cycle
Refer to Information Common to the G3J, G3J-T, and G3J-S.
55 A
66 A
44 A
55 A
380 to 400 VAC, 2.2 kW,
5.5 A
Motors passing the AC3-class, AC4-class, and AC53-a-class switching frequency test (Ta = 40°C)
under conditions specified by OMRON. Refer to Information Common to the G3J, G3J-T, and G3J-S.
200 to 400 VAC, 5.5 A
Rated supply
voltage
G3J-S405BL
No-voltage input
(open and short-
circuit input)
Input method
96 A, 60 Hz, 1 cycle
2.4 A (Ta = 40°C)
24 A
28.8 A
19.2 A
24 A
380 to 400 VAC,
0.75 kW, 2.4 A
200 to 400 VAC, 2.4 A
G3J-S403BL
2.2 kW (5.5 A)
0.75 kW (2.4 A)
2.2 kW (11.1 A)
0.75 kW (4.8 A)
Applicable motor
200 to 240 VAC (50/60 Hz)
180 to 264 VAC (50/60 Hz)
11.1 A (Ta = 40°C)
350 A, 60 Hz, 1 cycle
111 A
133.2 A
88.8 A
111 A
200 to 220 VAC, 2.2 kW,
11.1 A
200 to 240 VAC, 11.1 A 200 to 240 VAC, 4.8 A
G3J-S211BL
380 to 400 VAC
200 to 220 VAC
4.8 A (Ta = 40°C)
150 A, 60 Hz, 1 cycle
48 A
57.6 A
38.4 A
48 A
200 to 220 VAC,
0.75 kW, 4.8 A
G3J-S405BL
G3J-S403BL
G3J-S211BL
G3J-S205BL
G3J-S205BL
Model
G3J-S
2