DT6-4 Marlow Industries, Inc., DT6-4 Datasheet - Page 2

no-image

DT6-4

Manufacturer Part Number
DT6-4
Description
Marlow Industries Inc. Thermoelectric Cooler
Manufacturer
Marlow Industries, Inc.
Datasheet
Thermoelectric Cooler
Performance Curves
Installation
C o n s u l t Ma r l o w I n d u s t r i e s ’ T h e r mo e l e c t r i c I n s t a l l a t i o n G u i d e o r r e l i a b i l i t y r e p o r t f o r mo r e d e t a i l s . F o r a d d i t i o n a l
information, please contact one of our application engineers for technical support.
Operation Cautions
Maximum storage and operation +150°C.
For maximum reliability, storage and operation below 85°C is recommended. Excessive power cycling and powering
through thermostatic (on/off) control is not recommended.
Copyright 2000, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0158, Rev C
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our
Internet:
Dallas Texas 75238-1645
Marlow Industries, Inc.
10451 Vista Park Road
FAX: 214-341-5212
TEL: 214-340-4900
www.marlow.com
80.0
60.0
40.0
20.0
0.0
8.0
6.0
4.0
2.0
0.0
0.0
Hot Side Temperature: 27°C
1.0
CURRENT (AMPS)
TA(C)= 27
2.0
Environment: One atmosphere dry nitrogen
3.0
4.0
Aberdeen House, South Road
West Sussex RH164NG UK
Marlow Industries Europe
FAX: +44 (0)1444-443334
TEL: +44 (0)1444-443404
Applications Engineers.
5.0
Haywards Heath
HEAT
LOAD
(WATTS)
0.00
2.50
5.00
7.50
10.0
12.5
15.0
Q=0
T=0
80.0
60.0
40.0
20.0
10.0
0.0
8.0
6.0
4.0
2.0
0.0
0.0
Hot Side Temperature: 50°C
1.0
CURRENT (AMPS)
2.0
TA(C)= 50
3.0
Marlow Industries Asia
FAX: +81 (3) 5454-5281
TEL: +81 (3) 5454-5280
Tokyo, Japan 151-0064
Uehara, Shibuya-ku
4.0
1-1-8-401
5.0
HEAT
LOAD
(WATTS)
0.00
2.50
5.00
7.50
10.0
12.5
15.0
Q=0
T=0
DT6-4

Related parts for DT6-4