MIM-5335K5F Unity Opto Technology Co., Ltd., MIM-5335K5F Datasheet - Page 6

no-image

MIM-5335K5F

Manufacturer Part Number
MIM-5335K5F
Description
Infrared Receiver Module
Manufacturer
Unity Opto Technology Co., Ltd.
Datasheet
Unity Opto Technology Co., Ltd.
High temparature
High temp. & high humi.
Low temparature
Heat cycle
Dropping
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
NOTE 2. (electro-optical charactistics) shall be satisfied after leaving 2 hours in the normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
CAUTION ( When use and storage of this device )
Reliability
Inspection standard
Others
INFRARED RECEIVER MODULE
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
1.Among electrical characteristics , total number shall be inspected on items blow.
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
, the soldering iron is connected to ground before using .
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
covering the said problem .
Test item
and destructions of appearance .(excepting deforms of terminals)
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
Ta=+80
Ta=+40
Ta= -25
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
-25
o
C(0.5H) ~ +80
hite fluorescense lamp of no high frequency lighting.
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
o
o
o
C
C 90%RH
C
o
C(0.5H) 20cycle
Test condition
t=240H
t=240H
t=240H
Standard
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
MIM-5xx5K5F
01/12/2004
REV: A1

Related parts for MIM-5335K5F