CMMDW24S3.3-5500 Wall Industries,Inc., CMMDW24S3.3-5500 Datasheet

no-image

CMMDW24S3.3-5500

Manufacturer Part Number
CMMDW24S3.3-5500
Description
20 Watt Single Output Chassis Mount Dc/dc Converter 4 1 Ultra Wide Input Voltage Range
Manufacturer
Wall Industries,Inc.
Datasheet
FEATURES
● Output Current up to 5.5A
● Fixed Switching Frequency
● Six-Sided Continuous Shielding
● 20 Watts Maximum Output Power
● 4:1 Ultra Wide Input Voltage Range
● Options: Negative Logic Remote ON/OFF
● Call Factory for More Output Power Options
● Compliant to RoHS EU Directive 2002/95/EC
● CE Mark Meets 2006/95/EC, 93/68/EEC, and 89/336 EEC
● Chassis Mount Options: Open Frame, U Channel, and Enclosed Types Available
SPECIFICATIONS: CMMDW Series
All specifications apply @ 25°C ambient unless otherwise noted
INPUT SPECIFICATIONS
Input Voltage Range ............ 24V nominal input .......................... 9-36VDC
Input Voltage Variation......... dv/dt ............................................ 5V/ms max
Input Surge Voltage (100ms max) ....... 24V input ...........................50VDC
Input Reflected Ripple Current (nominal Vin and full load) ...........20mAp-p
Start Up Time (nominal Vin and constant resistive load)
Start Up Voltage................... 24V input.............................................9 VDC
Shutdown Voltage................ 24V input .........................................7.5 VDC
Remote ON/OFF (Note 6)
Input Current of Remote Control Pin (nominal Vin) ........ -0.5mA ~ +0.5mA
Remote Off Input Current (nominal Vin) ...........................................2.5mA
OUTPUT SPECIFICATIONS
Output Voltage ..............................................................................see table
Voltage Accuracy (nominal Vin and full load) ...................................... ±1%
Voltage Adjustability............................................................................. 10%
Output Current ..............................................................................see table
Output Power ........................................................................ 20 watts max.
Line Regulation (LL to HL at FL)....................................................... ±0.2%
Load Regulation (no load to full load) ............................................... ±0.5%
Minimum Load ....................................................................................... 0%
Ripple/Noise (20 MHz BW) ...........................................................see table
Transient Response Recovery Time (25% load step) .......................250us
PROTECTION SPECIFICATIONS
Over Voltage Protection........... 3.3V output ........................................ 3.9V
(zener diode clamp)
Over Load Protection (% of full load at nominal input)................ 150% typ.
Short Circuit Protection. ...................................Hiccup, automatic recovery
(measured with a 0.1uF/50V MLCC)
Power Up................................................................................20ms typ.
Remote ON/OFF ....................................................................20ms typ.
(Positive Logic)............... DC-DC ON ................Open or 3V < Vr < 12V
(Negative Logic) ............. DC-DC ON ...............Short or 0V < Vr < 1.2V
48V nominal input ........................ 18-75VDC
48V input...........................................18 VDC
48V input ..........................................15 VDC
DC-DC OFF .............Short or 0V < Vr < 1.2V
DC-DC OFF ..............Open or 3V < Vr < 12V
12V output ......................................... 15V
15V output ......................................... 18V
5V output ........................................ 6.2V
Due to advances in technology, specifications subject to change without notice
(Complies with ETS300 132 part 4.4)
48V input .........................100VDC
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
APPLICATIONS
● Measurement
● Wireless Network
● Telecom/Datacom
● Industry Control System
● Semiconductor Equipment
Rev B
GENERAL SPECIFICATIONS
Efficiency ........................................................................................see table
Switching Frequency .................................................................400KHz typ.
Isolation Voltage (Input to Output)......................................... 1600VDC min.
Isolation Voltage (Input to case) ............................................ 1600VDC min.
Isolation Voltage (Output to Case) ........................................ 1600VDC min.
Isolation Resistance ...............................................................10
Isolation Capacitance .............................................................. 1500pF max.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature ................................. -40°C ~ +66°C (w/o derating)
Storage Temperature .......................................................... -55°C ~ +125°C
Maximum Case Temperature ............................................................. 105°C
Relative Humidity...................................................................5% to 95% RH
Thermal Impedance (Note 7)
Thermal Shock ..................................................................... MIL-STD-810F
Temperature Coefficient ................................................... ±0.02% / °C max.
Vibration ................................10~55Hz, 10G, 30 minutes along X, Y, and Z
MTBF (Note 1)............BELLCORE TR-NWT-000332..........1.691 X 10
PHYSICAL SPECIFICATIONS
Potting material of the DC/DC Converter ..........................Epoxy (UL94-V0)
Shielding of the DC/DC Converter.................................................. six-sided
Weight ............................................................................Approximately 6 oz
Dimensions............................................ 4.00(L) x 2.25(W) x 0.81(H) inches
SAFETY & EMC
Approvals and Standards .................. IEC60950-1, UL60950-1, EN60950-1
EMI .............................EN55022 ...................................................... Class A
ESD ....................EN61000-4-2……..
Radiated Immunity..............EN61000-4-3............... 10V/m Perf. Criteria A
Fast Transient.....................EN61000-4-4................. ±2KV Perf. Criteria B
Surge ..................................EN61000-4-5................. ±1KV Perf. Criteria B
Conducted Immunity...........EN61000-4-6............ 10 Vrms Perf. Criteria A
Natural Convection ............................................................. 12°C / Watt
Natural Convection with Heat-Sink..................................... 10°C / Watt
MIL-STD-217F ................................. 5.629 x 10
4:1 Ultra Wide Input Voltage Range
Chassis Mount DC/DC Converter
Contact ± 6KV
Air ± 8KV
+66°C ~ +105°C (w/ derating)
20 Watt Single Output
CMMDW Series
…….Perf. Criteria B
9
ohms min.
6
5
hrs
hrs

Related parts for CMMDW24S3.3-5500

CMMDW24S3.3-5500 Summary of contents

Page 1

FEATURES ● Output Current up to 5.5A ● Fixed Switching Frequency ● Six-Sided Continuous Shielding ● 20 Watts Maximum Output Power ● 4:1 Ultra Wide Input Voltage Range ● Options: Negative Logic Remote ON/OFF ● Call Factory for More Output ...

Page 2

... OUTPUT VOLTAGE / CURRENT RATING CHART Output Model Number Input Range Voltage CMMDW24S3.3-5500 3.3 VDC CMMDW24S5-4000 24 VDC (9-36 VDC) CMMDW24S12-1670 12 VDC CMMDW24S15-1330 15 VDC CMMDW48S3.3-5500 3.3 VDC CMMDW48S5-4000 48 VDC (18-75 VDC) CMMDW48S12-1670 12 VDC CMMDW48S15-1330 15 VDC NOTES 1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC (Ground fixed and controlled environment). ...

Page 3

MECHANICAL DRAWING Unit: inches [mm] Rev B 2.25 [57.2] 1.13 [28.6] 3.66 [93.0] .16 [4.06] 2X Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 CMMDW Series 20 Watt Single Output Chassis Mount DC/DC Converter ...