PIC16F819 Microchip Technology Inc., PIC16F819 Datasheet - Page 24

no-image

PIC16F819

Manufacturer Part Number
PIC16F819
Description
18/20-pin Enhanced Flash Microcontrollers With Nanowatt Technology
Manufacturer
Microchip Technology Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC16F819
Manufacturer:
MIC
Quantity:
699
Part Number:
PIC16F819-1/P
Manufacturer:
MIC
Quantity:
20 000
Part Number:
PIC16F819-E/SO
Manufacturer:
ZETTLER
Quantity:
201
Part Number:
PIC16F819-E/SS
Manufacturer:
MICROCHIP
Quantity:
12 000
Part Number:
PIC16F819-E/SS
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
PIC16F819-I/P
Manufacturer:
MICROCHIP
Quantity:
1 000
Part Number:
PIC16F819-I/P
0
Part Number:
PIC16F819-I/SO
0
Part Number:
PIC16F819-I/SS
Manufacturer:
MICROCHIP
Quantity:
8 000
Part Number:
PIC16F819-I/SS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
PIC16F818/819
2.2.2.8
The Power Control (PCON) register contains a flag bit
to allow differentiation between a Power-on Reset
(POR), a Brown-out Reset, an external MCLR Reset
and WDT Reset.
REGISTER 2-8:
DS39598E-page 22
Note:
bit 7-2
bit 1
bit 0
Interrupt flag bits get set when an interrupt
condition occurs regardless of the state of
its corresponding enable bit or the Global
Interrupt Enable bit, GIE (INTCON<7>).
User software should ensure the appropri-
ate interrupt flag bits are clear prior to
enabling an interrupt.
PCON Register
PCON: POWER CONTROL REGISTER (ADDRESS 8Eh)
Unimplemented: Read as ‘0’
POR: Power-on Reset Status bit
1 = No Power-on Reset occurred
0 = A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
BOR: Brown-out Reset Status bit
1 = No Brown-out Reset occurred
0 = A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs)
bit 7
Legend:
R = Readable bit
-n = Value at POR
U-0
U-0
U-0
W = Writable bit
‘1’ = Bit is set
U-0
Note:
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
BOR is unknown on Power-on Reset. It
must then be set by the user and checked
on subsequent Resets to see if BOR is
clear, indicating a brown-out has occurred.
The BOR status bit is a ‘don’t care’ and is
not necessarily predictable if the brown-
out circuit is disabled (by clearing the
BOREN bit in the Configuration word).
U-0
U-0
 2004 Microchip Technology Inc.
x = Bit is unknown
R/W-0
POR
R/W-x
BOR
bit 0