TIP-3526PCS-8 Vishay, TIP-3526PCS-8 Datasheet - Page 4

no-image

TIP-3526PCS-8

Manufacturer Part Number
TIP-3526PCS-8
Description
Infrared Touch Panels, Rs232c Interface
Manufacturer
Vishay
Datasheet
Document Number: 37026
Revision 05-Dec-00
Enable ENTER point mode (22)
*Disable ENTER point mode (23)
This coordinate reporting mode will report the coordinates of the point where a stylus is entered into the touch panel. This
mode
can be used individually or in combination with EXIT point, CONTINUOUS or TRACKING modes. The following report
format
is used. If more than one stylus enters the touch panel,
a non-contiguous report will be generated.
Enable EXIT point mode (20)
*Disable EXIT point mode (21)
This coordinate reporting mode will report the coordinate of the point where a stylus is removed from the touch panel. This
mode can be used individually or in combination with ENTER point, CONTINUOUS or TRACKING modes. The following
report format
is used. If more than one stylus enters the touch panel, a
non-contiguous report will be generated.
Enable TRACKING/disable CONTINUOUS mode (34)
This coordinate reporting mode will report the coordinates of a stylus that remains in the touch panel, but only as the stylus
changes locations. This mode can be used individually or in combination with ENTER point or EXIT modes. The following
report format is used.
If more than one stylus enters the touch panel, a non-contiguous report will be generated.
RESPONSE (Code received from touch panel)
RESPONSE
Successful baud rate selection
(autobaud only)
DC1, Ctl Q, XON Software
Handshaking
DC3, Ctl S, XOFF Software
Handshaking
CONTINUOUS touch coordinates, X, Y
- binary X and Y, > = 0
- X, Y = FE if non-contiguous
ENTER touch coordinate, X, Y
- binary X and Y, > = 0
- X, Y = FE if non-contiguous
EXIT touch coordinates, X, Y
- binary X and Y, > = 0
- X, Y = FE if non-contiguous
TRACKING touch coordinates, X, Y
- binary X and Y, > = 0
- X, Y = FE if non-contiguous
No coordinate report available
Failed beams, bad photo pairs, end
RS-232 error (overrun or framing)
Model Number, string, end
- aaaa = variable length ASCII string
Software revision number, string, end
- aaa = variable length ASCII string
Matrix size, max X + 1, max Y + 1
Buffer overflow error
42 = start of enter report
xx yy = binary X and Y, > = 0, X, Y = FE if non-contiguous
43 = start of exit report
xx yy = binary X and Y, > = 0, X, Y = FE in non-contiguous
4E = start of coordinates report
xx yy = binary X and Y, > = 0, X, Y = FE if non-contiguous
CODE (HEX)
40
11
13
41 xx yy
42 xx yy
43 xx yy
4E xx yy
48
47 aa-nn FF
45
50 aaaa FF
4C aaa FF
4D xx yy
4F
TIP-3526PCS-8
Vishay Dale
CODE (ASCII)
@
DC1
DC3
A
B
C
N
H
G
E
P
L
M
O
www.vishay.com
5